Table 4.

CLABSI rates and unadjusted comparisons across levels of self-reported compliance with specific central line infection prevention policies in 2011/mid-2012

ICU type No. of
ICUs
99 (100%)
Mean (SD) 95% CI P value*
Central line bundle insertion checklist
  ≥ 95% compliance 48 (48) 1.24 (0.96) 0.96–1.52 Ref
  75-94% compliance 12 (12) 1.88 (1.51) 0.92–2.84 0.07
  25-74% compliance 2 (2) 1.96 (0.86) 0–9.65 0.51
  Do not know 12 (12) 1.40 (1.08) 0.71–2.08 0.91
  No monitoring 12 (12) 1.58 (0.66) 1.16–2 0.29
  No response to question 13 (13) 1.82 (1.61) 0.85–2.79 0.32
Optimal catheter site
  ≥ 95% compliance 45 (45) 1.21 (0.96) 0.93–1.5 Ref
  75-94% compliance 15 (15) 2.14 (1.44) 1.34–2.93 0.03
  25-74% compliance 1 (1) 1.54 (-) 0.79
  Do not know 12 (12) 1.36 (1.24) 0.57–2.16 0.93
  No monitoring 12 (12) 1.31 (0.8) 0.81–1.82 0.89
  No response to question 14 (14) 1.78 (0.98) 1.21–2.34 0.11
Chlorhexidine skin disinfection
  ≥ 95% compliance 51 (52) 1.32 (1.07) 1.02–1.62 Ref
  75-94% compliance 13 (13) 1.56 (1.06) 0.91–2.2 0.48
  25-74% compliance 1 (1) 0 (-) 1
  Do not know 14 (14) 1.05 (0.79) 0.6–1.51 0.19
  No monitoring 11 (11) 1.66 (0.82) 1.11–2.21 0.57
  No response to question 9 (9) 2.65 (1.37) 1.6–3.71 0.09
Barrier precautions
  ≥ 95% compliance 56 (57) 1.3 (0.97) 1.04–1.56 Ref
  75-94% compliance 9 (9) 1.9 (1.47) 0.77–3.03 0.13
  25-74% compliance 0
  Do not know 13 (13) 1.38 (1.06) 0.74–2.02 0.85
  No monitoring 13 (13) 1.41 (0.87) 0.88–1.93 0.85
  No response to question 8 (8) 2.4 (1.51) 1.14–3.66 0.23
Monitoring hand hygiene practices
  ≥ 95% compliance 57 (58) 1.28 (0.96) 1.03–1.54 Ref
  75-94% compliance 8 (8) 2.56 (1.4) 1.38–3.73 0.035
  25-74% compliance 0
  Do not know 13 (13) 1.38 (1.06) 0.74–2.02 0.88
  No monitoring 12 (12) 1.31 (0.8) 0.81–1.82 0.92
  No response to question 9 (9) 2.33 (1.54) 1.14–3.51 0.24
Checking line for daily necessity
  ≥ 95% compliance 40 (40) 1.27 (1.03) 0.94–1.6 Ref
  75-94% compliance 16 (16) 1.83 (1.12) 1.23–2.42 0.05
  25-74% compliance 3 (3) 1.72 (0.58) 0.27–3.16 0.43
  Do not know 10 (10) 1.32 (1.26) 0.42–2.22 0.84
  No monitoring 13 (13) 1.46 (0.9) 0.92–2.01 0.66
  No response to question 17 (17) 1.11 (1.17) 0.51–1.71 0.98
All bundle policies
  ≥ 95% compliance with all policies 25 (25) 1.3 (1.35) 0.74–1.86 Ref
  ≥ 95% compliance with 5 policies 16 (16) 1.21 (0.74) 0.82–1.61 0.87
  ≥ 95% compliance with 4 policies 10 (10) 1.2 (0.71) 1.69–1.71 0.95
  ≥ 95% compliance with 3 policies 8 (8) 1.55 (0.94) 0.77–2.34 0.35
  ≥ 95% compliance with 2 policies 0
  ≥ 95% compliance with 1 policy 1 (1) 3.92 (-) 0.32
  All other responses 39 (39) 1.77 (1.26) 1.37–2.18 0.23

CLABSI, central line-associated bloodstream infection; ICU, intensive care unit; SD, standard deviation No hospital reported <25% compliance with any policy; thus this compliance level not shown.

*

Unadjusted negative binomial regression using the sum of line device days as exposure variable to examine the association between ≥ 95% compliance with that central line bundle policy and other degrees of self-reported compliance (or other survey response)