Table 4.
ICU type | No. of ICUs 99 (100%) |
Mean (SD) | 95% CI | P value* |
---|---|---|---|---|
Central line bundle insertion checklist | ||||
≥ 95% compliance | 48 (48) | 1.24 (0.96) | 0.96–1.52 | Ref |
75-94% compliance | 12 (12) | 1.88 (1.51) | 0.92–2.84 | 0.07 |
25-74% compliance | 2 (2) | 1.96 (0.86) | 0–9.65 | 0.51 |
Do not know | 12 (12) | 1.40 (1.08) | 0.71–2.08 | 0.91 |
No monitoring | 12 (12) | 1.58 (0.66) | 1.16–2 | 0.29 |
No response to question | 13 (13) | 1.82 (1.61) | 0.85–2.79 | 0.32 |
Optimal catheter site | ||||
≥ 95% compliance | 45 (45) | 1.21 (0.96) | 0.93–1.5 | Ref |
75-94% compliance | 15 (15) | 2.14 (1.44) | 1.34–2.93 | 0.03 |
25-74% compliance | 1 (1) | 1.54 (-) | – | 0.79 |
Do not know | 12 (12) | 1.36 (1.24) | 0.57–2.16 | 0.93 |
No monitoring | 12 (12) | 1.31 (0.8) | 0.81–1.82 | 0.89 |
No response to question | 14 (14) | 1.78 (0.98) | 1.21–2.34 | 0.11 |
Chlorhexidine skin disinfection | ||||
≥ 95% compliance | 51 (52) | 1.32 (1.07) | 1.02–1.62 | Ref |
75-94% compliance | 13 (13) | 1.56 (1.06) | 0.91–2.2 | 0.48 |
25-74% compliance | 1 (1) | 0 (-) | – | 1 |
Do not know | 14 (14) | 1.05 (0.79) | 0.6–1.51 | 0.19 |
No monitoring | 11 (11) | 1.66 (0.82) | 1.11–2.21 | 0.57 |
No response to question | 9 (9) | 2.65 (1.37) | 1.6–3.71 | 0.09 |
Barrier precautions | ||||
≥ 95% compliance | 56 (57) | 1.3 (0.97) | 1.04–1.56 | Ref |
75-94% compliance | 9 (9) | 1.9 (1.47) | 0.77–3.03 | 0.13 |
25-74% compliance | 0 | – | – | |
Do not know | 13 (13) | 1.38 (1.06) | 0.74–2.02 | 0.85 |
No monitoring | 13 (13) | 1.41 (0.87) | 0.88–1.93 | 0.85 |
No response to question | 8 (8) | 2.4 (1.51) | 1.14–3.66 | 0.23 |
Monitoring hand hygiene practices | ||||
≥ 95% compliance | 57 (58) | 1.28 (0.96) | 1.03–1.54 | Ref |
75-94% compliance | 8 (8) | 2.56 (1.4) | 1.38–3.73 | 0.035 |
25-74% compliance | 0 | – | – | |
Do not know | 13 (13) | 1.38 (1.06) | 0.74–2.02 | 0.88 |
No monitoring | 12 (12) | 1.31 (0.8) | 0.81–1.82 | 0.92 |
No response to question | 9 (9) | 2.33 (1.54) | 1.14–3.51 | 0.24 |
Checking line for daily necessity | ||||
≥ 95% compliance | 40 (40) | 1.27 (1.03) | 0.94–1.6 | Ref |
75-94% compliance | 16 (16) | 1.83 (1.12) | 1.23–2.42 | 0.05 |
25-74% compliance | 3 (3) | 1.72 (0.58) | 0.27–3.16 | 0.43 |
Do not know | 10 (10) | 1.32 (1.26) | 0.42–2.22 | 0.84 |
No monitoring | 13 (13) | 1.46 (0.9) | 0.92–2.01 | 0.66 |
No response to question | 17 (17) | 1.11 (1.17) | 0.51–1.71 | 0.98 |
All bundle policies | ||||
≥ 95% compliance with all policies | 25 (25) | 1.3 (1.35) | 0.74–1.86 | Ref |
≥ 95% compliance with 5 policies | 16 (16) | 1.21 (0.74) | 0.82–1.61 | 0.87 |
≥ 95% compliance with 4 policies | 10 (10) | 1.2 (0.71) | 1.69–1.71 | 0.95 |
≥ 95% compliance with 3 policies | 8 (8) | 1.55 (0.94) | 0.77–2.34 | 0.35 |
≥ 95% compliance with 2 policies | 0 | – | – | |
≥ 95% compliance with 1 policy | 1 (1) | 3.92 (-) | – | 0.32 |
All other responses | 39 (39) | 1.77 (1.26) | 1.37–2.18 | 0.23 |
CLABSI, central line-associated bloodstream infection; ICU, intensive care unit; SD, standard deviation No hospital reported <25% compliance with any policy; thus this compliance level not shown.
Unadjusted negative binomial regression using the sum of line device days as exposure variable to examine the association between ≥ 95% compliance with that central line bundle policy and other degrees of self-reported compliance (or other survey response)