Published in final edited form as: Phys Med Biol. 2015 Apr 23;60(9):3807–3824. doi: 10.1088/0031-9155/60/9/3807

Table 2.

NRMSE for estimated 3D fluoroscopic images based on 4DCT motion models and 4DCBCT motion models, respectively for eight patients’ datasets. The initial NRMSE is the normalized RMSE of the ground truth images at different phases and the reference image. The final NRMSE is between the 3D fluoroscopic image and ground truth.

Dataset
no.
4DCT 4DCBCT

Initial
NRMSE
Final
NRMSE
Initial
NRMSE
Final
NRMSE

1 0.17 0.10 0.14 0.10
2 0.13 0.09 0.11 0.08
3 0.22 0.15 0.17 0.17
4 0.13 0.09 0.10 0.08
5 0.15 0.09 0.12 0.09
6 0.09 0.07 0.07 0.06
7 0.14 0.09 0.11 0.09
8 0.17 0.09 0.13 0.10

Average 0.15 0.10 0.12 0.10