Table 3.

Mechanical and Biomaterial Properties in GATA-1low/low X OPG−/− and C57BL/6 Mice

Mice n Stiffness (N/mm) Polar Moment of Inertia (mm4) Ultimate Failure (MPa) Load at Peak (N) Modulus (GPa) Toughness (MJ/m3) Energy to Ultimate Force (mJ)
C57BL/6 24 129.7±3.6b,c 0.34±0.07a,b,c 244±5b,c 22.5±0.1a,b,c 47±1a,b,c 3.3±0.1c 9.9±0.3a,b,c
GATA-1low/low 9 135.3±6.7e 0.27±0.02a,e 269±45d,e 25.7±0.7a,d,e 58±3a,d,e 2.9±0.2 7.2±0.6a,d
OPG−/− 6 21.7±5.3b,d 0.25±0.02b,f 106±26b,d 9.6±0.7b,d 11±3b,d 2.7±0.8 4.6±1.2b,d
GATA-1low/low X OPG−/− 12 41.1±3.7c,e 0.46±0.06c,e,f 90±8c,e 6.6±1.1c,e 13±2c,e 1.9±0.3c 6.2±0.6c

Results are presented as mean ± SEM.

a

GATA-1low/low, p < 0.05 compared with C57BL/6

b

OPG X OPG−/−, p < 0.05 compared with C57BL/6

c

GATA-1low/low x OPG−/−, p < 0.05 compared with C57BL/6

d

OPG−/−, p < 0.05 compared with GATA-1low/low

e

GATA-1low/low X OPG−/−, p < 0.05 compared with GATA-1low/,ow

f

GATA-1low/low X OPG−/−, p < 0.05 compared with OPG−/−