Table 1.

Specification comparison between proposed system and other BCI-based multimedia controller.

BCI System SSVEP BCI Multimedia Control [15] Proposed BCI-Based Multimedia Controller
EEG Signal SSVEP EEG spectra in theta rhythm
Transmission RF transmission Bluetooth
Power Supply Power line 3.7 V Li Battery
Sampling Rate 8 kHz 512 Hz
Gain 1000 5000
Analog Filter 20–22 Hz 0.1–100 Hz
Backend Signal Processing Unit FPGA board Mobile tablet
Control Mode Active BCI [22] Passive BCI [22]
Multimedia Applications Music Music