Skip to main content
. Author manuscript; available in PMC: 2015 May 18.
Published in final edited form as: Proc SPIE Int Soc Opt Eng. 2009 Feb 18;7164:71640O. doi: 10.1117/12.809024

Table 1.

Parameter list for Photofrin and values at 630 nm

Symbol Definition [4]
k0 Photon absorption rate of sensitizer per sensitizer concentration
k1 Bimolecular rate for 1O2 reaction with ground-state photosensitizer
k2 Bimolecular rate of triplet sensitizer quenching by 3O2
k3 Decay rate of first excited singlet state sensitizer to ground state sensitizer
k4 Rate of monomolecular decay of the sensitizer triplet state
k5 Rate of first excited triplet state sensitizer to ground state sensitizer
k6 1O2 to 3O2 decay rate
k7 Bimolecular rate of reaction of 1O2 with biological substrate [A]
Symbol Definition Value References
SΔ Fraction of triplet-state sensitizer-3O2 reactions which produce 1O2 0.5 [4]
δ Low concentration correction term 33 (μM) [7]
ε Extinction coefficient of sensitizer 0.0035 (cm−1 μM−1) [2]
α k7[A]/k6 0.95 [3]*
β k4/k2 11.9 (μM) [3]
γ k5/(k3 + k5) 0.8 [2]
κ k1/k6 7.2 × 10−5 (μM−1) [3]*
η ε/hν 0.0019 (cm2 mW−1 s−1) based on [2]
SΔγηα/(1+α)** 0.0037 (cm2 mW−1 s−1) [3]*
*

The calculation of the parameter values are based on tumor spheroid studies [3].

**

This value corresponds to the oxygen consumption rate per light fluence (in mW/cm2) per initial sensitizer concentration (in μM).