Table 2.

Scanners and the scanning protocols used for healthy and nonsevere asthmatic and severe asthmatic subjects in different institutions

Imaging Center Center 1 Center 2 Center 3 Center 4
Scanner model Siemens Sensation 64 slice GE VCT 64 slice Siemens Sensation 16 Slice GE
Scan type Spiral Helical Spiral Helical
Rotation time, s 0.5 0.5 0.5 0.5
Detector configuration channel no. × mm 64 × 0.6 mm 64 × 0.625 mm 16 × 0.75 mm 16 × 1.25 mm
Pitch 1.0 0.984 1.5 1.675
Peak kilovoltage, kVp 120 120 120 120
Siemens = effective mAs* Effective mA Effective mA 50
GE = mAs* mAs 100 S-145; M-180; L-270 mAs 33
Dose modulation Care dose OFF Auto mA OFF Care dose OFF Smart mA off
Reconstruction algorithm B35 Standard or detail B30 Standard or detail
Lung algorithm None None None None
Additional image filters No selection No selection No selection No selection
Thickness, mm 0.75 0.625 1.0 1.25
Interval, mm 0.5 0.5–0.625 0.5–1.0 0.625
Iterative reconstruction (noise reduction algorithm) No selection No selection No selection No selection
Scan Time (30-cm length), s <10 <10 <15 <20

GE, General Electric; mAs, millampere second.

*

mA was varied for center 2 protocol based on BMI size [small (S): BMI <20; medium (M): 20 ≤ BMI ≤30, large (L): BMI >30].