Table 4. Sequences used in the magnetic resonance enterography protocol.

  Repetition time/echo time (ms) Flip angle Slice thickness (mm) In plane resolution (mm) Distance factor (Axial) (mm) Distance factor (Coronal)(mm)
True Fast Imaging with Steady-state free Precession (FISP) 4/1,72 60° 4,0 2,0 × 1,5 0 0,4
Single shot turbo spin echo sequence with fat suppression (HASTE) 1100/116 150° 6,0 1,5 × 1,6 1,8
Retro Steady State Free Precession 42,6/1,2 73° 6,0 1,5 × 2 6,0
Fat-suppressed 3D T1-weighted Volumetric Interpolated Breath-Hold Examination (VIBE) before and three times - 30, 90 seconds and 5 minutes after intravenous injection of gadolinium contrast (Gadovist 1.0, Bayer Pharma AG, Germany, dose of 0.1 mmol/kg body weight followed by 20 ml of saline) 6,10/2,74 10° 1,75 2 × 2 0,6 0,6