Skip to main content
. 2015 May 7;3(2):e21. doi: 10.2196/medinform.4397

Table 2.

Performance of R-wave peak detection algorithm.

Characteristics of dataset and algorithm n or %
Type of beats, n

Total beats 109,494

True positives 109,371

False negatives 73

False positives 134
Algorithm performance measure, %

Detection error rate 0.19

Positive prediction rate 99.88

Sensitivity 99.93