Table 1. Summary of Imaging Parameters.

Acquisition TR (ms) TE1 (ms) TE2 (ms) Flip Angle Matrix FOV (mm) Coil No.
Phantom at 3T
 LEENA FISP 5.0 1.95 3.05 45° 256 × 176 300 × 225 12
 LEENA-S (r) FISP 3.1 1.55 45° 128 × 88 300 × 225 12
 LEENA-G (c) FISP 4.1 1.5 2.6 45° 64 lines 300 × 675 12
Human liver at 1.5T
 LEENA FISP 5.23 1.52 3.72 45° 256 × 175 400 × 275 9
 LEENA-S (r) FISP 2.29 1.15 45° 128 × 88 400 × 275 9
 LEENA-G (c) FISP 4.51 1.15 3.35 45° 64 lines 400 × 825 9
 2PD GRE 7 2.42 4.62 25° 256 × 175 400 × 275 9
 Fat suppression GRE 24 2.42 25° 256 × 175 400 × 275 9
Human liver at 3T
 LEENA FISP 4.6 1.75 2.85 45° 256 × 192 400 × 300 20
 LEENA-S (r) FISP 3.52 1.76 45° 128 × 96 400 × 300 20
 LEENA-G (c) FISP 3.58 1.24 2.34 45° 64 lines 400 × 900 20
 2PD GRE 8 2.2 5.5 25° 256 × 192 400 × 300 20
 Fat suppression GRE 22 2.25 25° 256 × 192 400 × 300 20
Human leg at 3T
 LEENA FISP 4.6 1.75 2.85 45° 256 × 192 500 × 375 20
 LEENA-S (r) FISP 3.52 1.76 45° 128 × 96 500 × 375 20
 LEENA-G (c) FISP 3.58 1.24 2.34 45° 64 lines 500 × 1125 20
 2PD GRE 8 2.2 5.5 25° 256 × 192 500 × 375 20
 Fat suppression GRE 22 2.25 25° 256 × 192 500 × 375 20