Global sensitivity analysis parameter inputs and quantitative output indices.

Parameters Lower bound Upper bound Variance (%) Total effect
CLF_UIM* 7.87E-02 2.11E-01 17.60 23.00
KMNIS_I* 1.33E+04 4.46E+04 12.00 15.70
VMAXNISF_THY_MI* 1.22E+03 5.64E+03 12.00 17.00
KDEGT4F_MI* 1.03E-04 2.52E-04 10.20 13.60
FRCONVT4_MI* 5.67E-05 1.14E-04 8.03 10.10
BW_M* 5.69E+01 8.33E+01 7.57 10.20
VDFT4_MI 7.69E-02 1.63E-01 6.45 8.05
QFTHY_MI 5.43E-03 2.66E-02 5.58 9.23
QFC_MI 9.48E+00 2.17E+01 2.15 3.76
CLFT4_MI 5.66E-05 3.13E-04 1.77 3.34
KPRODT4F_MI 6.85E-07 4.21E-06 0.44 0.67
FRCONVT4_FI 1.56E-05 2.24E-04 0.43 1.24
VDFT4_FI 1.21E-01 5.99E-01 0.33 0.64
KDEGT4F_FI 2.13E-03 5.47E-03 0.24 0.42
QFRP_MI 4.51E-01 8.37E-01 0.18 0.31
PFT4PLC_MI 5.93E-01 2.29E+00 0.14 0.25
PPLCPF_MI 1.65E-01 6.35E-01 0.09 0.25
PAFT4PLCF_MI 1.12E-04 4.48E-04 0.08 0.19
PAFPLCBTOT_MI 3.04E-02 1.30E-01 0.06 0.13
PPLC_MI 1.65E-01 6.35E-01 0.06 0.12
VMAXNISF_THY_FI 9.75E+02 6.82E+03 0.06 0.13
BW_F 2.53E+00 4.27E+00 0.03 0.09
PAFPLCTTOB_MI 3.04E-02 1.30E-01 0.02 0.04
KPRODT4F_FI 8.24E-05 3.18E-04 0.00 0.00
IODSTORES_MG_MI 6.81E+00 2.24E+01 0.00 0.00
VMAXNISF_PLC_MI 2.85E+02 1.22E+03 0.00 0.00
*

Parameter ranges optimized for physiologically plausible sampling space for global sensitivity analysis.