Skip to main content
. 2015 May 27;10(5):e0128146. doi: 10.1371/journal.pone.0128146

Table 1. Reported pre- and post-operative intraocular pressure in studies included in meta-analysis.

Author (Year) Study Design Study Location Number of iStent N Follow-up (months) Mean Age Age (SD) Baseline IOP (Mean) Baseline IOP (SD) Outcome IOP (Mean) Outcome IOP (SD) IOPR% SD_IOPR%
Ahmed (2012) [ 40 ] Case Series Canada 1 30 6 - - 23.3 1.3 16.1 4.4 31 12
Case Series Canada 2 30 6 - - 23.2 0.9 13.7 2.5 41 11
Case Series Canada 3 30 6 - - 23.2 2.4 13.6 2.1 41 14
Buznego (2009)[ 32 ] Cohort U.S. 1 41 18 - - 21.5 6.9 16.7 6.9 22 45
Charters (2013)[ 30 ] RCT U.S. 2 39 - - - 30 4.0 13.2 0.0 56 13
Singh (2012)[ 41 ] Case Series Canada 2 39 6 73 0 19.1 3.8 15.1 2.7 21 24
Case Series Canada 2 39 12 73 0 19.1 3.8 15.9 0.9 17 20
Voskanyan (2014)[ 39 ] Case Series France, Germany, Italy, Republic of Armenia, Spain 1 99 1 66.4 10.9 26.3 3.5 17 6.4 41 18
Case Series France, Germany, Italy, Republic of Armenia, Spain 1 99 3 66.4 10.9 26.3 3.5 16.6 4.5 41 18
Case Series France, Germany, Italy, Republic of Armenia, Spain 1 99 6 66.4 10.9 26.3 3.5 16.8 4.1 41 18
Case Series France, Germany, Italy, Republic of Armenia, Spain 1 99 7 66.4 10.9 26.3 3.5 15.8 3.2 41 18
Case Series France, Germany, Italy, Republic of Armenia, Spain 1 99 9 66.4 10.9 26.3 3.5 15.5 3 41 18
Case Series France, Germany, Italy, Republic of Armenia, Spain 1 99 12 66.4 10.9 26.3 3.5 15.7 3.7 41 18

Weighted mean reduction in IOPR% following two iStents implantation at 6-months: 30.