Skip to main content
. 2015 May 19;2015:610482. doi: 10.1155/2015/610482

Table 2.

Results of automatically identifying fusion events.

Fusion events ground truth
(TP + FN)
Fusion events detected
(TP + FP)
Mistakenly identified
(FP)
Missed
(FN)
Recall Precision False +ve
Sequence 1 47 42 6 11 76.6% 85.7% 7.1%
Sequence 2 62 59 7 10 83.9% 88.1% 8.5%
Sequence 3 89 83 9 15 83.1% 89.2% 10.0%

Average 81.2% 87.7% 8.5%