Table 2.
Falsified tablets | Weight (0.228–0.252 g)* | Diameter (9.1–9.2 mm)† | Thickness (3.0–3.4 mm)* | Pass/Fail‡ |
---|---|---|---|---|
CF #1 | 306 | 9.2 | 3.4 | Fail |
CF #2 | 241 | 9.2 | 3.2 | Pass |
CF #3 | 343 | 9.2 | 3.7 | Fail |
CF #4 | 304 | 10 | 3.7 | Fail |
CF #5 | 260 | 9.3 | 3.5 | Fail |
CF #6 | 243 | 9.2 | 3.2 | Pass |
CF = counterfeit.
Bold/italic figures were used to emphasize values that were out-of-range for the Coartem specifications.
Coartem tablet specifications per Novartis personal communication.
Range as determined from 12 authentic tablets.
Pass = tablet measurements within all three ranges; fail = tablet measurement outside of at least one range.