Study characteristics
Patient sampling Cross‐sectional design; consecutive sampling
Patient characteristics and setting Species: S. haematobium
Country: Ethiopia
Sample size: 156
Age range: 0 to > 40 years
Participants: all residents invited for checkup (low endemic area)
Setting: field study
Praziquantel status before study: not reported
Index tests RS‐Microhaematuria (Multistix Reagent Strips, Ames‐Miles, Elkhart, IN, USA)
Target condition and reference standard(s) S. haematobium infection measured by urine microscopy (filtration method)
Flow and timing  
Comparative  
Notes  
Methodological quality
Item Authors' judgement Risk of bias Applicability concerns
DOMAIN 1: Patient Selection
Was a consecutive or random sample of patients enrolled? Yes    
Was a case‐control design avoided? Yes    
Did the study avoid inappropriate exclusions? Unclear    
    Unclear Low
DOMAIN 2: Index Test RS‐Microhaematuria
Were the index test results interpreted without knowledge of the results of the reference standard? Unclear    
If a threshold was used, was it pre‐specified? No    
Was quality control done? Unclear    
    Unclear Low
DOMAIN 3: Reference Standard
Is the reference standards likely to correctly classify the target condition? Unclear    
Were the reference standard results interpreted without knowledge of the results of the index tests? Unclear    
Was quality control done? Unclear    
    Unclear Low
DOMAIN 4: Flow and Timing
Was there an appropriate interval between index test and reference standard? Unclear    
Did all patients receive the same reference standard? Yes    
Were all patients included in the analysis? Unclear    