Skip to main content
. 2015 Jun 5;20(6):066002. doi: 10.1117/1.JBO.20.6.066002

Table 1.

Simulation results of accuracy of fitted second layer properties. The first layer properties are the true values given in the first column.

First layer (cm1) Second layer (cm1)
  1. μa=0.1, μs=6.0 2. μa=0.2, μs=6.0
1. μa=0.02, μs=4.0 μaμs 97.9% 76.3% 85.0% 63.2%
2. μa=0.05, μs=6.0 μaμs 97.5% 93.4% 86.3% 66.1%
3. μa=0.05, μs=9.0 μaμs 90.0% 61.3% 77.7% 43.4%