Skip to main content
. 2015 Jun 5;10(6):e0128743. doi: 10.1371/journal.pone.0128743

Table 4. Activation in auditory cortex during speech stimulation versus multi-tone complex stimulation.

Patient no., auditory implant, speech score Activation in PET a
Side x b y b z b Z value T value BA41 c BA42 c BA22 c BA21 c
No. 1, CI left, 82% left -70 -38 4 5.22 14.23 0 0 959 1414
right 64 -10 0 5.75 20.01 0 0 846 1216
No. 2, ABI 1 left, 58% left -64 -50 12 4.14 9.28 0 59 365 394
right 58 2 52 5.11 18.59 0 415 1358 1510
No. 3, ABI 2 left, 55% left -74 -30 16 6.62 30.30 0 0 991 1437
right 34 42 -30 5.16 12.19 0 0 343 448
No. 5, AMI 2 left, 0% left -68 -54 -14 5.32 15.10 256 407 1145 2259
right 64 -50 14 4.43 8.88 0 133 256 154

a Threshold for statistical inferences: p<0.001.

b MNI coordinates.

c Voxels in Brodmann Areas.