Skip to main content
. 2004 Jul;42(7):3159–3163. doi: 10.1128/JCM.42.7.3159-3163.2004

TABLE 3.

Comparative results of positive TaqMan based PCR assay samples processed by using HLGT and the QIAamp DNA blood kit with blood culture and antigen Candida detection results

Patient no. DNA load (102 CFU/ml of blood)a
Blood culture result Candida antigen concn (ng/ml) Blood originb
C. albicans
C. parapsilosis
C. tropicalis
C. glabrata
HLGT QIA HLGT QIA HLGT QIA HLGT QIA
1 -d - - - - - 2.8 2.8 C. glabrata PAC
1 - - - - - - 10.3 10.1 C. glabrata 1.220 PAC
2 2.6 2.5 - - - - - - C. albicans PAC
2 4 4 - - - - - - C. albicans 0.300 PAC
3 2.5 3.2 - - - - - - C. albicans >2 CVC
3 10 10 - - - - - - C. albicans CVC
4 3.4 4.2 - - - - - - NDc >2
5 0.7 0.7 - - - - - - >2 CVC
6 - - - - 13 12 - - C. tropicalis >2 PAC
7 - - 6.3 7.3 - - - - C. parapsilosis PAC
8 6 4 - - - - - - C. albicans PAC
9 3 2.7 - - - - - - C. albicans 1.300 PER
10 18.4 17.1 - - - - - - ND 1.081
11 13.5 13.1 - - - - - - ND 1.470
12 13.3 10.5 - - - - - - ND 0.540
13 7.7 7.6 - - - - - - ND 0.860
14 3 4 - - - - - - ND 0.600
15 1.3 1.8 - - - - - - ND 0.260
16 1.1 1.9 - - - - - - ND 0.350
17 0.7 0.6 - - - - - - ND 0.290
a

QIA, QIAamp DNA blood kit.

b

PAC, Port-a-Cath implantable intramuscular device; PER, peripheral blood; CVC, central venous catheter.

c

ND, not done.

d

-, negative result.