Table 1.
Time | Mean (sec) | N | SEM | P |
---|---|---|---|---|
Before room entry | ||||
Fully compliant | 59.9 | 21 | 7.15 | 1.000 |
Partially compliant | 43.2 | 103 | 6.92 | .288 |
Non-compliant | 3.2 | 56 | 2.16 | <.001 |
Non-isolation room | 0.0 | 9 | 0 | <.001 |
In room | ||||
Fully compliant | 507.3 | 23 | 82.26 | 1.000 |
Partially compliant | 375.0 | 108 | 37.18 | .140 |
Non-compliant | 149.7 | 54 | 73.72 | .006 |
Non-isolation room | 28.4 | 7 | 50.29 | .027 |
After room exit | ||||
Fully compliant | 15.2 | 21 | 6.33 | 1.000 |
Partially compliant | 12.6 | 127 | 2.74 | .722 |
Non-compliant | 1.3 | 89 | 0.81 | <.001 |
Non-isolation room | 0.5 | 9 | 0.38 | .145 |
Note. Completion of all contact isolation precaution tasks in the correct order before room entry and after room exit was considered full compliance. Completing at least one, but not all, contact isolation tasks was considered partial compliance. Failure to complete any contact isolation tasks was considered non-compliance.