Table 2.
Accuracy of the automated AE detection algorithms
Accuracy measures | VTE [39] | Pneumonia [40] | In-hospital fall [41] | |
---|---|---|---|---|
DVT | PE | |||
Coefficient (95%CI) | Coefficient (95%CI) | Coefficient (95%CI) | Coefficient (95%CI) | |
Sensitivity (%) | 80 (76–85) | 79 (73–85) | 83 (80–86) | 83 (81–85) |
Specificity (%) | 98 (97–99) | 99 (98–99) | 98 (97–99) | 100 (100–100) |
PPV (%) | 89 (85–93) | 84 (75–92) | 89 (84–93) | 100 (100–100) |
NPV (%) | 96 (93–99) | 98 (98–99) | 97 (96–97) | 99 (98–99) |
DVT deep vein thrombosis, NPV negative predictive value, PE pulmonary embolism, PPV positive predictive values, VTE venous thromboembolism