Published in final edited form as: Phys Med Biol. 2012 Dec 7;58(1):127–144. doi: 10.1088/0031-9155/58/1/127

Table 4.

Coefficients for determining the rupture threshold of a resonant sized UCA via (5). ‘1 cycle’ and ‘Steady State’ refers to single cycle and steady state acoustic excitations, respectively. The goodness-of-fit parameters coefficient of determination r2 and standard error σ are also shown.

UCA Fluid Deviations from
ambient pressure
(mmHg)
Acoustic
excitation
a1 a2 r2 σ (MPa)
Definity Water 0 1 cycle 1.56 6.98 × 10−3 0.993 3.10 × 10−3
Definity Water 0 Steady state 0.708 3.60 × 10−2 0.994 3.40 × 10−3
Definity Blood 0 1 cycle 1.46 8.02 × 10−3 0.993 3.00 × 10−3
Definity Blood 0 Steady state 1.03 2.00 × 10−2 0.992 4.00 × 10−3
Definity Blood 95 1 cycle 1.49 7.55 × 10−3 0.991 3.00 × 10−3
Definity Blood 95 Steady state 0.994 2.17 × 10−2 0.992 4.00 × 10−3
Definity Blood 130 1 cycle 1.50 7.44 × 10−3 0.991 3.40 × 10−3
Definity Blood 130 Steady state 0.991 2.19 × 10−2 0.992 3.90 × 10−3
Optison Blood 0 1 cycle 1.33 5.95 × 10−3 0.997 1.40 × 10−3
Optison Blood 0 Steady state 1.17 9.03 × 10−3 0.994 2.10 × 10−3
Sonazoid Blood 0 1 cycle 1.16 1.66 × 10−2 0.993 3.60 × 10−3
Sonazoid Blood 0 Steady state 1.03 2.16 × 10−2 0.997 2.30 × 10−3