Radiographic outcomes following stenting for IIH.

Author/year Number of patients Number of stentings Average radiographic follow-up (months) Number of in-stent stenoses Subsequent treatment Number of out-of-stent stenoses Subsequent treatment
Higgins et al. 2002 [4] 1 1 1 0 0 0 0
Owler et al. 2003 [5] 9 4 3 0 0 1 0
Higgins et al. 2003 [6] 12 14 NR 2 Thrombolytic therapy NR NR
Ogungbo et al. 2003 [7] 1 1 12 0 0 0 0
Rajpal et al. 2005 [8] 1 1 6 0 0 0 0
Donnet et al. 2008 [9] 10 11 6 0 0 0 0
Paquet et al. 2008 [10] 1 1 NR NR NR NR NR
Arac et al. 2009 [11] 1 1 2 0 0 0 0
Bussière et al. 2010 [12] 10 13 NR NR NR NR NR
Zheng et al. 2010 [13] 1 1 NR NR NR NR NR
Ahmed et al. 2011 [14] 52 60 NR 0 0 6 Resenting in 6 patients
Albuquerque et al. 2011 [15] 15 30 12.5 0 0 1 Restenting
Kumpe et al. 2012 [16] 18 19 25.3 0 0 4 Restenting in 1 patient
Teleb et al. 2012 [17] 1 1 12 0 0 0 0
Radvany et al. 2013 [18] 12 12 NA 0 0 2 Restenting in 2 patients and 1 patient requiring VPS
Characteristics Number of patients Number of stentings Average radiographic follow-up (95% CI) Number of in-stent stenoses (%; 95% CI) Subsequent treatment (%) Number of out-of-stent stenoses Subsequent treatment
Fields et al. 2013 [19] 15 15 9 0 0 0 0
Ducruet et al. 2014 [20] 30 36 22 4 0 5 0
Summary 185 221 15.2 (13.6–16.8)1 6 (3.4; 2.5–4.3)2 1 (0.6) 19 (11.4; 10.4–12.4)3 10 (6.0; 5.1–6.9)3

1Reported in 11 studies (N = 102).

2Reported in 14 studies (N = 178).

3Reported in 13 studies (N = 166).

Refers to 1 patient who received thrombolytic therapy. Not patients received restenting.