Table 2.
Platform ID1 | Mode | Total features | Discriminating features from independent analysis | Number of identified standard molecules2 | Discriminating features from CCSWA (r > 0.8) | Features shared by both methods | %1 of shared features | Discriminating features from CCSWA (r > 0.9) | Features shared by both methods | %3 of shared features |
---|---|---|---|---|---|---|---|---|---|---|
N1 | – | 751 | 86 | 22 | 188 | 65 | 35 | 103 | 50 | 49 |
N2 | – | 252 | 93 | 24 | 43 | 33 | 77 | 30 | 22 | 73 |
N3 | – | 88 | 36 | 16 | 37 | 23 | 62 | 21 | 13 | 62 |
N4 | – | 9,699 | NR | 345 | – | 66 | ||||
N5a | – | 233 | 133 | 23 | 110 | 68 | 62 | 60 | 43 | 72 |
O1P | Pos | 5,035 | 25 | 798 | – | 552 | ||||
Q6P | Pos | 1,922 | 354 | 22 | 820 | 102 | 12 | 398 | 38 | 9.5 |
Q6N | Neg | 314 | 137 | 14 | 69 | 43 | 62 | 27 | 19 | 70 |
O3P | Pos | 1,827 | 265 | 23 | 194 | 194 | 100 | 158 | 158 | 100 |
O3N | Neg | 1,715 | 348 | 25 | 222 | 222 | 100 | 177 | 177 | 100 |
O4P | Pos | 2,668 | 11 | 433 | – | 256 | ||||
Q1P | Pos | 1,181 | 118 | 21 | 129 | 108 | 84 | 104 | 95 | 91 |
Q1N | Neg | 1,288 | 210 | 13 | 171 | 171 | 100 | 152 | 152 | 100 |
Q2P | Pos | 1,688 | 440 | NR | 472 | 415 | 88 | 388 | 373 | 96 |
Q2N | Neg | 2,492 | 153 | NR | 268 | 149 | 56 | 203 | 143 | 70 |
Q3P | Pos | 908 | 167 | 13 | 184 | 83 | 45 | 144 | 66 | 46 |
Q4P | Pos | 909 | 202 | 23 | 176 | 85 | 48 | 151 | 74 | 49 |
Q4N | Neg | 438 | 74 | 15 | 58 | 58 | 100 | 52 | 52 | 100 |
Q5Pa | Pos | 6,992 | 2215 | 20 | 1431 | 1430 | 100 | 970 | 970 | 100 |
Q5Na | Neg | 5,167 | 1137 | 22 | 475 | 474 | 100 | 257 | 257 | 100 |
T1Pa | Pos | 580 | 192 | 22 | 139 | 139 | 100 | 117 | 117 | 100 |
T1Na | Neg | 398 | 101 | 14 | 77 | 77 | 100 | 66 | 66 | 100 |
Total number of features, number of discriminating features per statistical method and number of discriminating features shared by the two statistical methods for each instrument
aThese instruments are located on the same platform
1N for NMR spectrometer, Q for QTOF mass spectrometer, O for Orbitrap mass spectrometer, T for TOF mass spectrometer. The P or N appended to the mass spectrometer identifier number denotes positive or negative ionisation mode, respectively
2Annotated standard molecules detected by each laboratory are reported in online resource Table 3; annotation was performed only on features that statistically differed in the spiked samples, except for partners O1, Q2 and N4 (NR for non-reported)
3The percentage of discriminating features (selected by the CCSWA) that were also selected as discriminating by the simple statistical analysis carried out by each participating laboratory