Skip to main content
. 2015 Jun 8;2015:813242. doi: 10.1155/2015/813242

Table 1.

Studies considering the influence of PCO on test results.

Author (year) [reference number] Test n Precapsulotomy BCVA
(mean ± SD)
Postcapsulotomy BCVA
(mean ± SD)
Results after capsulotomy
García-Medina et al. (2006) [14]. AP 26 0.35 ± 0.11
(decimal scale)
0.84 ± 0.14
(decimal scale)
MD and PSD improved.

García-Medina et al. (2006) [23] SLP 28 0.41 ± 0.12
(decimal scale)
0.85 ± 0.13
(decimal scale)
NFI and TSS increased. Significant decreases of all absolute parameters.

Vetrugno et al. (2007) [24] SLP 158 0.3 ± 0.6
(LogMar)
0.05 ± 0.2
(LogMar)
Inferior ratio and TSNIT SD decreased. Superior/nasal increased.

Brittain et al. (2007) [25] SLP 20 0.32 ± un
(LogMar)
0.14 ± un
(LogMar)
TSS and TSNIT SD increased. TSNIT score decreased.

Arraes et al. (2008) [26] SLP 37 0.2 ± un
(decimal scale)
0.8 ± un
(decimal scale)
No significant difference between parameters.

Hougaard et al. (2001) [35] TD-OCT 13 0.29 ± un
(decimal scale)
0.39 ± un
(decimal scale)
Signal-to-noise ratio increased but no changes in macular thickness.

Garcia-Medina et al. (2007) [32] TD-OCT 32 0.25 ± 0.17
(decimal scale)
0.77 ± 0.22
(decimal scale)
SS increased but no changes in pRNFL thicknesses (in reliable exams).

González-Ocampo-Dorta et al. (2008) [40] TD-OCT 32 0.25 ± 0.17
(decimal scale)
0.77 ± 0.22
(decimal scale)
SS increased but no changes in macular thicknesses (in reliable exams).

Altiparmak et al. (2010) [36] TD-OCT 54 0.47 ± 0.3
(decimal scale)
0.91 ± 0.14
(decimal scale)
No change of the foveal thickness.

Giocanti-Aurégan et al. (2011) [37] TD-OCT 30 0.6 ± 0.3
(LogMar)
0.1 ± 0.3 
(LogMar)
No change of the foveal thickness.

Wróblewska-Czajka et al. (2012) [38] TD-OCT 55 NA NA No change of the central macular thickness.

Kara et al. (2012) [31] TD-OCT 98 0.49 ± 0.28
(LogMar)
0.09 ± 0.11
(LogMar)
SS and pRNFL thicknesses increased.

Garcia-Medina et al. (2013) [34] SD-OCT 37 0.27 ± 0.19 
(decimal scale)
0.83 ± 0.18 
(decimal scale)
All pRNFL thickness parameters increased. No changes when considering reliable examinations.

Garcia-Medina et al. (2013) [41] SD-OCT 35 0.23 ± 0.28
(decimal scale)
0.81 ± 0.16
(decimal scale)
All macular thickness parameters increased. No changes when considering reliable examinations.

Ruiz-Casas et al. (2013) [39] SD-OCT 31 0.4 ± NA 0.8 ± NA No change of the foveal thickness.

BCVA: best-corrected visual acuity, SD: standard deviation, AP: automated perimetry, MD: mean deviation, PSD: pattern standard deviation, SLP: scanning laser polarimetry, NFI: nerve fiber indicator, TSS: typical scan score, TSNIT: temporal-superior-nasal-inferior-temporal, NA: not available, TD-OCT: time domain optical coherence tomography, SD-OCT: spectral domain optical coherence tomography, SS: signal strength, and pRNFL = peripapillary retinal nerve fiber layer.