Definition for effective thresholds λd; tested variation ranges, optimal values according to our investigations, and previously suggested values in the literature for common thresholds λc.

Detector Threshold definition for λd Tested range for λc Optimal value for λc Suggested in literature for λc
RSP λc_RSP [0.1, 0.5] 0.3 0.22
RMS percentilec, fdRMS) [0.7, 0.995] 0.92 0.95
Sigma λc_SIGMA [1.0, 8.0] 4.0 4.5
Teager λc_TEAGER*fd_TEAGER¯ [0.5, 8.0] 3.0 0.6

All effective decision thresholds are applied directly to the corresponding detection functions fd. The percentile(p, s) function computes the percentile p of the distribution of a signal s. fd_TEAGER¯ stands for the average value of fd_TEAGER.