Skip to main content
. 2015 Jun 11;14:240. doi: 10.1186/s12936-015-0746-8

Table 2.

Features of malaria laboratories in Aceh, Indonesia, 2010

Laboratory Components Aceh Barat Abdiya Aceh Besar Aceh Jaya Aceh Selatan Aceh Singkil Aceh Tamiang Aceh Tengah Aceh Tenggara Aceh Timur Aceh Utara Banda Aceh Bener Meriah Bireun Gayo Lues Langsa Lhokseumawe Nagan Raya Pidie Pidie Jaya Sabang Simeuleu Subulussalam
Number of Laboratories 13 14 24 10 13 10 16 19 14 29 28 23 12 22 14 9 8 11 20 10 10 10 5
Working space
  Facility and space o o o
  Limited access o o o o o o o o o o o o o o o
  Clean and tidy room o o
  Water supply o o o o o o o o o
  Electricity o o o o o o
Equipment
  Availability o o o o o o o
  Maintenance records o o o o o o o o o o o o o o o o o
  Calibration o o o o o o o o o o o o o o o o
  Storage o o o
Supplies
  Stock of supplies o o o o
  Quality check o o o o o o o o o o o o o o o o o
  Procurement o o o o o o o o o o o
Laboratory
  Efficient workflow o o o o
  Register book o o o o o
  Information updated o o o o o o o
SOPs
  Laboratory procedures o o o o
  Manual for equipment o o o o o
  SOP’s location o o o o o o o o o
  Reflect current work o o o o o o o o o
  Annually reviewed o o o o o o o o o o o o o o o o
HR and Trainings
  Microscopists o o o o o
  Refresher training o o o o o o o o o o o o
  Training documents o o o o o o o o o o o o o o o o o o o
  Microscopy trainings o o o o o o o o o o o o o
Collection and reporting
  Slides archiving o o o o
  Reporting o o o o o
  Cross-checking o o o o o o o o o o o o o o o o
Safety
  Sharp container o o o o o o o
  Laboratory coat o o o o o o o o o o o o o o
  Handwash soap o o o o o o o o o

●: High adequacy; score ≥ 70 %

o: Less adequacy, score < 70 %

: No response