Skip to main content
. 2015 Jul;6(3):142–149. doi: 10.1177/1947603515573987

Table 3.

Osteochondral Allograft Magnetic Resonance Imaging Scoring System (OCAMRISS) Scheme.

MRI Feature MRI Score
Cartilage features 1. Cartilage signal of graft 0: Normal
1: Altered intensity (either hypointense or hyperintense, but not fluid)
2: Fluid signal intensity on all sequences
2. Cartilage “fill” of graft (percentage of volume) 0: 76% to 100%
1: 51% to 75% or >100%
2: <50%
3. Cartilage edge integration at host- graft junction 0: No discernible boundary
1: Discernible boundary
2: Discernible fissure >1 mm
4. Cartilage surface congruity of graft and host-graft junction 0: Flush
1: <50% offset of host cartilage
2: >50% offset of host cartilage
5. Calcified cartilage integrity of graft 0: Intact, thin, and smooth
1: Altered (disrupted, thickened, or blurred)
Bone features 6. Subchondral bone plate congruity of graft and host-graft junction 0: Intact and flush
1: Disrupted or not flush by >1 subchondral thickness
7. Subchondral bone marrow signal intensity of graft relative to epiphyseal bone 0: Normal
1: Abnormal (bone marrow edema pattern or hypointensity on all sequences)
8. Osseous integration at host-graft junction 0: Crossing trabeculae
1: Discernible cleft
9. Presence of cystic changes of graft and host-graft junction 0: Absent
1: Present
Ancillary features 10. Opposing cartilage 0: Normal
1: Abnormal
11. Meniscal tears 0: Absent
1: Present
12. Synovitis 0: Absent
1: Present
13. Fat pad scarring 0: Absent
1: Present