. 2015 Jun 28;21(24):7563–7570. doi: 10.3748/wjg.v21.i24.7563

Table 3.

Agreement of lactose malabsorption and lactose intolerance diagnosis between 4-sample lactose hydrogen breath testing and standard lactose hydrogen breath testing methods

Standard LHBT
4SLHBT LM LI
IBS-D (+) (-) Kappa P value (+) (-) Kappa P value
10 g (+) 23 0 0.931 < 0.001 10 0 0.942 < 0.001
(-) 2 35 1 49
20 g (+) 50 0 0.870 < 0.001 26 0 0.933 < 0.001
(-) 2 8 2 32
40 g (+) 55 0 0.880 < 0.001 47 0 0.839 < 0.001
(-) 1 4 3 10
HVs
10 g (+) 19 0 0.925 < 0.001 2 0 1.000 < 0.001
(-) 2 39 0 58
20 g (+) 46 0 0.902 < 0.001 12 0 0.949 < 0.001
(-) 2 12 1 47
40 g (+) 53 0 0.815 < 0.001 38 0 0.889 < 0.001
(-) 2 5 3 19

LHBT: Lactose hydrogen breath test; LM: Lactose malabsorption; LI: Lactose intolerance; 4SLHBT: 4-Sample Lactose Hydrogen Breath Testing; IBS-D: Irritable bowel syndrome patients with diarrhea; HVs: Healthy volunteers.