Skip to main content
. 2015 May 20;16(4):523–534. doi: 10.1007/s10162-015-0521-0

TABLE 1.

Acoustic psychophysical detection thresholds. Means of thresholds measured over the time period when the MPI and TI data were collected and up to the time of sacrifice are shown. NR = no response at the highest levels of stimulation tested

Subject 8 kHz sinusoids (dB SPL) 16 kHz sinusoids (dB SPL) 24 kHz sinusoids(dB SPL)
335L1 62.9 39.1 39.3
345L1 37.7 29.2 18.8
347L1 52.7 60.0 40.6
348L1 55.1 67.6 73.7
350L1 65.9 39.1 58.5
351L1 50.9 48.2 49.6
353L1 48.4 39.6 29.5
361L1 72.5 42.4 82.3
374L1 37.6 25.1 34.1
390L1 72.5 75.0 75.0
399L1 75.1 73.1 NR
407L1 80.9 NR NR
411L2 60.7 55.0 49.9
412L1 NR NR NR
421L1 50.9 61.0 67.7
422L1 61.5 28.2 42.4
423L1 32.0 38.8 44.4
436L2 91.3 NR NR
453L1 42.6 9.6 22.9
456L1 89.1 NR NR
Mean 60.0 45.7 48.6
STD 17.2 18.5 19.4
N 19 16 15