Some of the main optogenetic tools for sensing cellular activity.

Protein Excitation/emission wavelengths (nm) Action References
(a) Voltage sensors
FlaSh 450/510 Voltage sensor 44
VSFP1 440/480 and 530 Voltage sensor 45
VSFP2.3 440/480 and 530 Voltage sensor 46
SPARC 470/500 to 550 Voltage sensor 47
hVOS 480/520 Voltage sensor 48
ElectricPK 485/510 Voltage sensor 49
ArcLight 485/510 Voltage sensor 50
PROPS 550/700 Voltage sensor 51
Arch 560/690 Voltage sensor 41
Arch(D95N) 585/690 Voltage sensor 41
QuasAr1/QuasAr2 590/715 Voltage sensor 26
Archer1/Archer2 655/>680 Voltage sensor 33
MacQ-mCitrine 500/530 and 580 Voltage sensor 52
MacQ-mOrange2 530/560 and 580 Voltage sensor 52
Citrine eFRET GEVI (QuasAr2) 500/530 and 715 Voltage sensor 53
mOrange2 eFRET GEVI (QuasAr2) 530/560 and 715 Voltage sensor 53
mRuby2 eFRET GEVI (QuasAr2)
560/600 and 715
Voltage sensor
53
(b) Calcium sensors
GCaMPs 490/510 Calcium sensor 43,54
RCaMPs 570/585 Calcium sensor 55
G-Gecos 490/510 Calcium sensor 42,56
B-Gecos 375/450 Calcium sensor 42
R-Gecos 565/585 Calcium sensor 42
Twitch 435/470 and 530 Calcium sensor 57
GEM-GECO1 400/450 and 510 Ratiometric calcium sensor 42
GEX-GECO1 400 and 480/510 Ratiometric calcium sensor 42
REX-GECO1 480 and 570/585 Ratiometric calcium sensor 58
Cameleon derivatives (YCs) 435/470 and 530 Ratiometric calcium sensor 59
TN-XXL
435/480 and 530
Calcium sensor
60
(c) Others
FLIP-E 435/480 and 530 Glutamate sensor 61
iGluSnFrs 485/510 Glutamate sensor 62
Chlomeleon/Super Chlomeleon 435/470 and 530 Ratiometric chloride sensor 63,64
CNiFER 435/480 and 530 Acetylcholine sensor 65
pHRed 440 and 580/610 Ratiometric pH sensor 66
SE-pHluorin 400 and 475/510 pH sensor 67
pHuji 570/600 pH sensor 67
Perceval 405 and 490/530 ATP/ADP sensor 68
HyPer 430 and 500/520 H2O2 sensor 69