Skip to main content
. 2015 Jul 2;10(7):e0131011. doi: 10.1371/journal.pone.0131011

Table 6. The previously reported manually applied instrumentation that underwent a reliability analyses.

Author Pathology Investigated Signals Intra-rater Analysis Inter-rater Analysis Statistical Analysis
Lamontagne (1998) [40] SCI (n = 9) Biomechanical Within session analysis (1 second) Not performed ICC / CV
Pandyan (2001) [29] Stroke (n = 16) Biomechanical Within session analysis (10–15 seconds) Not performed ANOVA
Van Der Salm (2005) [28] SCI (n = 9) Biomechanical Within session analysis (5 seconds) Not performed ICC / CIs
Voerman (2007) [41] Stroke / Healthy(n = 12/11) Biomechanical Electrophysiological Between session analysis (10 minutes) Between session analysis (1 day) ICC
Turk (2008) [42] Stroke / Healthy(n = 12/12) Biomechanical Electrophysiological Between session analysis (unspecified time) Between session analysis (no waiting time) ICC / SRD / LOA
Wu (2010) [21] TD (n = 10) Biomechanical Between session analysis (1 day) Not performed ICC

SCI, Spinal Cord Injury; TD, Typically Developing; ICC, intra-class correlation coefficient; CV, coefficient of variation; CIs, confidence intervals; ANOVA, analysis of variance; SRD, smallest real difference; LOA, limits of agreement.