Skip to main content
. 2015 May 20;11:29. doi: 10.1186/s12990-015-0028-z

Fig. 5.

Fig. 5

Direct correlation between the AP parameters characterizing neuronal excitability and TCD in the capslpH+ DRG neurons. AP parameters were measured at the AP initiation threshold in Tyrode’s solution. TCD was measured in the same neurons at a voltage step from −100 to −50 mV when the external Tyrode’s solution was changed for TEA-Cl, Ba2+-based solution. a Significant correlation between the ADP/AHP area and TCD. Pearson coefficient Pc = 0.78, p < 1.2*10−5. Number of cells: n = 28 from eight rats b Significant correlation between the AP threshold and TCD. Pearson coefficient, Pc = 0.52, p < 0.0015. Number of cells: n = 36 from eight rats