Skip to main content
. 2015 Jun 21;2015:751703. doi: 10.1155/2015/751703

Table 3.

The predictive value of S-creatinine, S-creatinine ratio, and CCR for delayed MTX elimination.

Parameters AUC P value Cut-off Sensitivity Specificity
S-creatinine 24 h 0.756 (0.672–0.840) <0.001 >35.0 68.6% 70.1%
S-creatinine ratio 24 h 0.759 (0.668–0.850) <0.001 >1.129 69.8% 80.0%
CCR_24 h 0.771 (0.688–0.854) <0.001 <100.0 68.6% 74.1%
CCR ratio 24 h 0.728 (0.626–0.829) <0.001 <0.824 67.4% 73.1%
S-creatinine 0 h 0.422 (0.324–0.519) 0.130
CCR_0 h 0.509 (0.409–0.608) 0.859

S-creatinine 24 h: serum creatinine level in 24 hours after MTX infusion; S-creatinine ratio 24 h: the ratio of serum creatinine level in 24 hours to creatinine level before MTX infusion; CCR_24 h: creatinine clearance rate in 24 hours after MTX infusion; CCR ratio 24 h: the ratio of CCR in 24 hours to CCR before MTX infusion; S-creatinine 0 h: serum creatinine level before MTX infusion; CCR_0 h: creatinine clearance rate before MTX infusion.