Figure 8. Trial sequential analysis of clot retention.
A diversity adjusted information size of 2469 patients was calculated using a two side α = 5%, β = 20% (power 80%), D2 = 0%, an anticipated relative risk increase of 35% and an event propotion of 9% in the control arm. Trials with no events were included in the study with a constant continuity correction of 1.