Table 2.

Accuracy and reproducibility of segmental cardiac analysis with 3D-self-navigated CMR

N = 105 patients N with abnormal findings Agreement Obs 1 vs Gold standard Agreement Obs 2 vs Gold standard Agreement Obs 1 vs Obs 2
1. Atrial situs 1 100 % 100 % 100 %
2. Position of the apex 1 100 % 100 % 100 %
3. Atrial segment morphology 11 100 % 100 % 100 %
4. Atrio-ventricular connection 2 99 % 99 % 100 %
5. Ventricular segment morphology 6 100 % 99 % 99 %
6. Ventriculo-arterial connection 18 99 % 98.1 % 99 %
7. Anatomy of the thoracic aorta 25 100 % 100 % 100 %
8. Anatomy of the venous return 16 100 % 100 % 100 %
9. Intracardiac shunts 12 98.1 % 99 % 97.1 %
10. Course of the coronary arteries 4 100 % 98.1 % 98.1 %
Complete segmental anatomy
(Agreement = all 10 elements correctly evaluated) 96.2 % 93.3 % 93.3 %

Obs: Observer