TABLE 2.

Comparison of model-predicted measures of global function (volumes, changes in volume, fractional measures) in the normal left atrium to in vivo averages reported in Moyer et al.27.

Metric Simulation Measured Error (%)
Vmax (mL) 66 71±18 7
Vmin (mL) 27 29±11 7
VpreA (mL) 39 44±12 11

ΔVt (mL) 39 42±11 7
ΔVp (mL) 27 27±8 <1
ΔVa (mL) 12 15±6 20

EFt (%) 59 60±9 2
EFp (%) 41 38±7 8
EFa (%) 31 34±12 9

Vp/t (%) 69 65±10 6
Va/t (%) 31 35±10 11

Abbreviations: Vmax - volume maximum volume, Vmin - minimum, VpreA – volume just before the onset of active emptying, ΔVt – total change in volume, ΔVp – change in volume during passive emptying, ΔVa – change in volume during active emptying, EFt - total emptying fraction, EFa - active emptying fraction, EFp - passive emptying fraction, Vp/t - active emptying as a fraction of total, Va/t - active emptying as a fraction of total.