Table 1.

Structures configuration for a phantom suitable for proton therapy. The parameters for the S-Model are provided, whereas the organs name can be used to find the corresponding parameters of the LKB, CV, CE and Niemierko model.

Structure PTV Proximal PTV Proximal Penumbra Distal
Organ Glottic Nasopharynx Brachial plexus Brain Colon Spinal cord
Seriality Not applicable Not applicable 8.4 0.64 0.69 4
α/β 10 10 3 3 3 3
γ 1.6 1 2.8 2.6 3.1 1.9
TCD50 or TD50 (Gy) 44.2 40.9 75.1 60 55.3 68.6