Table 1.
Common and maximum experimental values. A typical particle diameter is one micrometer for many dielectrophoretic experiments. Geometric factors (insulator-based dielectrophoresis) include gate-widths between 100 nm and 30 mm, global applied fields of 104 V/m. These two factors and ranges therein allow for all calculated values.
Eave(V/m) | ∇|E|2ave(V2/m3) | dE/dxave(V/m2) | d∇|E|2/dxave(V2/m4) | ΔEmax/dx(V/m2) | Δ(∇|E|2max/dx)(V2/m4) |
---|---|---|---|---|---|
Common input values | |||||
1.4 × 105 | 9 × 1014 | −3.5 × 109 | 3.1 × 1019 | 1.3 × 107 | 2.5 × 1017 |
Highest experimentally accessible values | |||||
5.0 × 106 | 1.0 × 1018 | 3.5 × 1011 | 3.1 × 1020 | 1.6 × 108 | 1.1 × 1017 |