Skip to main content
. Author manuscript; available in PMC: 2015 Sep 1.
Published in final edited form as: Am J Psychiatry. 2014 Sep;171(9):949–959. doi: 10.1176/appi.ajp.2014.13091196

Table 3.

Mean and standard deviation (SD) for sensory measures for schizophrenia patients and controls

Measure Patient Control F df p d
Mean SD Mean SD
Tone matching (% correct) 74.4 12.4 87.8 9.5 14.6 1,54 <.001 −1.2
Visual Contrast Sensitivity (CS, 1/threshold)
 0.5 cycles/degree (c/d) 64.3 31.6 105.0 31.8 20.7 1,54 <.001 −1.3
 7 cycles/degree (c/d) 77.2 27.3 82.6 23.9 .53 1,54 .5 −.2
 21 cycles/degree (c/d) 2.8 1.7 3.4 1.7 1.71 1,54 .2 −.4
Mismatch negativity (MMN) amplitude (μV)
 Frequency deviant −2.4 1.8 −3.5 1.7 9.71 1,49 .037 −.9
 Duration deviant −2.4 2.0 −4.1 1.9 4.62 1,49 .003 −.6
 Intensity deviant −2.9 1.9 −4.5 2.1 7.71 1,49 .008 −.8