Skip to main content
. Author manuscript; available in PMC: 2015 Nov 1.
Published in final edited form as: J Bone Miner Res. 2014 Nov;29(11):2456–2467. doi: 10.1002/jbmr.2278

Table 2.

Diaphyseal Bone Parameters Measured by MicroCT for Strain-Matched (1200µe) Loading and Unloading Studies

Diaphyseal VOI Parameters Loading Study Unloading Study


WT Sost−/− WT Sost−/−




Control Loaded Control Loaded Control Unloaded Control Unloaded
37% Cortical BV (mm3) 0.55 ± 0.03 0.64 ± 0.03a 0.74 ± 0.05 0.88 ± 0.05a 0.50 ± 0.02 0.47 ± 0.02a 0.68 ± 0.06 0.68 ± 0.06
Ct.Th (mm) 0.26 ± 0.01 0.30 ± 0.01a 0.34 ± 0.00 0.39 ± 0.01a 0.24 ± 0.01 0.22 ± 0.00a 0.31 ± 0.01 0.31 ± 0.02
Ps (mm) 5.84 ± 0.26 6.14 ± 0.25a 6.06 ± 0.29 6.34 ± 0.29a 5.75 ± 0.19 5.68 ± 0.27 5.94 ± 0.33 5.95 ± 0.26
Ec (mm) 3.66 ± 0.14 3.74 ± 0.22 3.51 ± 0.26 3.69 ± 0.45 3.85 ± 0.23 4.11 ± 0.27b 3.95 ± 0.42 3.96 ± 0.30
MMI(polar) (mm4) 0.48 ± 0.06 0.60 ± 0.07a 0.67 ± 0.10 0.87 ± 0.11a 0.42 ± 0.03 0.41 ± 0.06 0.61 ± 0.10 0.62 ± 0.09
TMD (g/cm3) 1.47 ± 0.03 1.48 ± 0.04 1.56 ± 0.03 1.59 ± 0.02a 1.39 ± 0.04 1.39 ± 0.07 1.52 ± 0.03 1.52 ± 0.04
50% Cortical BV (mm3) 0.41 ± 0.02 0.49 ± 0.03a 0.60 ± 0.04 0.68 ± 0.05a 0.38 ± 0.01 0.36 ± 0.02a 0.56 ± 0.03 0.55 ± 0.03
Ct.Th (mm) 0.28 ± 0.00 0.32 ± 0.02a 0.37 ± 0.00 0.41 ± 0.01a 0.26 ± 0.00 0.24 ± 0.00a 0.36 ± 0.01 0.35 ± 0.01b
Ps (mm) 4.10 ± 0.16 4.42 ± 0.17a 4.66 ± 0.25 4.85 ± 0.22b 4.13 ± 0.14 4.05 ± 0.17 4.48 ± 0.23 4.51 ± 0.24
Ec (mm) 2.23 ± 0.12 2.31 ± 0.23 2.31 ± 0.36 2.29 ± 0.45 2.48 ± 0.19 2.50 ± 0.15 2.45 ± 0.33 2.35 ± 0.20
MMI(polar) (mm4) 0.19 ± 0.03 0.25 ± 0.03a 0.31 ± 0.05 0.37 ± 0.06a 0.17 ± 0.02 0.17 ± 0.02 0.28 ± 0.04 0.28 ± 0.03
TMD (g/cm3) 1.65 ± 0.03 1.64 ± 0.05 1.73 ± 0.04 1.74 ± 0.02 1.52 ± 0.05 1.53 ± 0.06 1.66 ± 0.04 1.67 ± 0.04
n 10 10 10 10 10 10 10 10
a

p < 0.01.

b

p < 0.05 compared to contralateral control.