Skip to main content
. 2014 Apr 23;14(Suppl 1):37–45. doi: 10.1007/s13191-014-0359-x

Table 2.

Comparison of microleakage between (a) CAD milled copings cemented with light cure and self cure resin bonding systems and (b) copy milled copings cemented with light cure and self cure bonding systems

CAD/COPY Light/self N Mean Rank Sum of Ranks Mann–Whitney U Wilcoxon W Z P Value
CAD milled L2/L1 Light cure 8 6.5 52 16 52 −1.684 0.105
Self cure 8 10.5 84
COPY milled L2/L1 Light cure 8 5.19 41.5 5.5 41.5 −2.86 0.003
Self cure 8 11.81 94.5
Light/self N Minimum Maximum 25th Percentile MEDIAN 75th IQR
CAD milled L2/L1 Light cured 8 0 0.11 0.0075 0.06 0.09625 0.08875
Self cured 8 0.02 0.6 0.049 0.135 0.2475 0.1985
COPY milled L2/L1 Light cured 8 0 0.06 0 0 0.0225 0.0225
Self cured 8 0.02 0.31 0.03125 0.105 0.1775 0.14625