Table 1. Description of assembly equipment and type of test performed.
Assay equipment | EMIC Modelo: DL10000 |
---|---|
Equipment capacity | 100kN |
Load cell capacity | 10kN |
Validity of the load cell calibration | 05/2013 |
Assay speed | 10 mm/min |
Room temperature during assay | 23 oC |
Distance between support and load applicator - L | 100.0 mm (± 0.01) |
Distance between parallel bars (Except configuration 1) | 40.0 mm (± 0.01) |
Material of the support blocks | Polyethylene UHMWPE |
Material of the intermediate block | Polyurethane with density 40PCF |