Published in final edited form as: J Chromatogr B Analyt Technol Biomed Life Sci. 2015 Feb 7;0:54–59. doi: 10.1016/j.jchromb.2015.01.034

Table 2.

Calibration curve, precession, recovery, and matrix effect of EZ.

Linear range
(nM)
Concentration (nM) Intra-day Inter-day Recovery Matrix Effect
Accuracy
(bias, %)
Precession
(CV %)
Accuracy
(bias, %)
Precession
(CV %)
Mean (%) SD Mean (%) SD
Plasma 10,000.00-4.88 9.75 102.80 5.06 119.35 12.87 97.63 7.80 87.04 11.67
312.5 101.20 4.97 115.89 12.50 82.71 3.37 85.50 8.59
5,000.00 106.65 6.20 114.73 11.05 80.50 13.95 100.70 7.63
Brain
tissue
10,000.00-4.88 9.75 91.19 12.43 89.27 4.83 98.58 12.17 90.47 13.97
312.5 108.00 7.46 104.45 2.66 105.22 13.59 98.13 12.00
5,000.00 106.22 2.14 107.11 4.30 106.23 5.74 100.44 5.59
HBSS
buffer
5,000.00-1.22 4.88 106.44 4.05 89.02 3.07 91.35 6.00 97.73 3.53
312.5 88.88 1.89 92.13 2.20 98.11 3.23 99.93 2.12
5,000.00 100.5 1.84 107.34 3.77 98.83 4.96 101.97 5.57