Table 1.

Summary of dosimetric data from all treatment plans that passed pre-enrollment credentialing.

Dosimetric
parameter
Mean
value
Range Protocol-Specified Compliance Criteria
Per
Protocol
Variation
Acceptable
Deviation
Unacceptable
PTV V95% 96.4% 94.0–99.7%
PTV D98% 26.3Gy 18.3–36.1Gy ≥25Gy <25Gy
PTV D90% 30.9Gy 30.0–36.6Gy <30.0Gy
PTV D2% 36.0Gy 31.7–39.8Gy ≤37.5Gy >37.5Gy, ≤40Gy >40.0Gy
Hippocampal maximum dose 14.8Gy 10.6–17.0Gy ≤16Gy ≤17Gy >17Gy
Hippocampal D100% 8.6Gy 6.3–10.0Gy ≤9Gy ≤10Gy >10Gy
Optic nerve maximum dose 32.8Gy 11.4–37.2Gy ≤37.5 Gy ≤37.5Gy >37.5Gy
Optic chiasm maximum dose 34.4Gy 31.0–37.4Gy ≤37.5 Gy ≤37.5Gy >37.5Gy