Skip to main content
International Journal of Environmental Research and Public Health logoLink to International Journal of Environmental Research and Public Health
. 2015 Jul 15;12(7):8075–8091. doi: 10.3390/ijerph120708075

The State of Ambient Air Quality in Two Ugandan Cities: A Pilot Cross-Sectional Spatial Assessment

Bruce J Kirenga 1,†,*, Qingyu Meng 2,, Frederik van Gemert 3, Hellen Aanyu-Tukamuhebwa 4, Niels Chavannes 5, Achilles Katamba 6, Gerald Obai 7, Thys van der Molen 3, Stephan Schwander 2,, Vahid Mohsenin 8,
Editor: Paul B Tchounwou
PMCID: PMC4515709  PMID: 26184273

Abstract

Air pollution is one of the leading global public health risks but its magnitude in many developing countries’ cities is not known. We aimed to measure the concentration of particulate matter with aerodynamic diameter <2.5 µm (PM2.5), nitrogen dioxide (NO2), sulfur dioxide (SO2), and ozone (O3) pollutants in two Ugandan cities (Kampala and Jinja). PM2.5, O3, temperature and humidity were measured with real-time monitors, while NO2 and SO2 were measured with diffusion tubes. We found that the mean concentrations of the air pollutants PM2.5, NO2, SO2 and O3 were 132.1 μg/m3, 24.9 µg/m3, 3.7 µg/m3 and 11.4 μg/m3, respectively. The mean PM2.5 concentration is 5.3 times the World Health Organization (WHO) cut-off limits while the NO2, SO2 and O3 concentrations are below WHO cut-off limits. PM2.5 levels were higher in Kampala than in Jinja (138.6 μg/m3 vs. 99.3 μg/m3) and at industrial than residential sites (152.6 μg/m3 vs. 120.5 μg/m3) but residential sites with unpaved roads also had high PM2.5 concentrations (152.6 μg/m3). In conclusion, air pollutant concentrations in Kampala and Jinja in Uganda are dangerously high. Long-term studies are needed to characterize air pollution levels during all seasons, to assess related public health impacts, and explore mitigation approaches.

Keywords: ambient air pollution, particulate matter, nitrogen dioxide, sulfur dioxide, ozone, Uganda, Kampala, Jinja

1. Introduction

On the 25 March 2014, the World Health Organization (WHO) released new estimates of the contribution of air pollution to global mortality showing that seven million deaths were attributable to air pollution worldwide in the year 2012 (3.7 million due to ambient air pollution (AAP) and 4.3 million due to indoor air pollution (IAP)) [1]. This number represents a doubling from the air pollution mortality rates estimated by WHO in the year 2004 [1,2].

Air pollution is thus one of the leading global public health risks. Health problems commonly associated with air pollution exposure include: respiratory diseases (e.g., chronic obstructive pulmonary disease, asthma, lung cancer and acute respiratory infections in children) and cardiovascular diseases (such as ischemic heart disease and stroke) [2]. Adverse health effects associated with air pollution exposure are particularly severe among vulnerable populations (e.g., people with respiratory diseases like asthma), older people, and children. Available data also show that airpollutionhasthepotential to impair lung growth as a result of perinatal exposures thus threatening the health of entire generations [3,4,5,6]. Although over 3000 substances are known to potentially contaminate air [7], the WHO has identified particulate matter (PM), nitrogen dioxide (NO2), carbon monoxide (CO), sulfur dioxide (SO2) and ozone (O3) as the pollutants with greatest public health importance [2]. The United States (US) National Ambient Air Quality Standard (NAAQS) [8] designates all of the above plus airborne lead (Pb) as criteria pollutants.

WHO and the US Environmental Protection Agency (USEPA) have defined guideline limits for these pollutants that should not be exceeded in order to maintain and protect public health [9,10]. The WHO limits for PM2.5, PM10, NO2, SO2, and O3 are 25 μg/m3 (24-hour mean), 50 μg/m3 (24-hour mean), 200 μg/m3 (one-hour mean), 20 μg/m3 (24-hour mean), and 100 μg/m3 (eight-hour mean), respectively [9], while the limits for the same pollutants set by the USEPA are PM2.5 35 μg/m3 (24-hour mean), PM10 150 μg/m3 (24-hour mean), NO2 100 ppb or 200 μg/m3 (one-hour mean), SO2 75 ppb or 150 μg/m3 (one-hour mean) and O3 0.075 ppm or 150 μg/m3 (one-hour mean) [10].

Data on the magnitude of air pollution in African cities is limited, particularly as it relates to Sub-Saharan Africa [11]. The WHO database provides an average PM2.5 value for Africa of 78 μg/m3 annual mean (which is almost three times the set limit) [12]. A detailed review of the database shows that 18 African studies, seven of which were from South Africa, were used in generating this average, indicating a dearth of data on air pollution for the African continent. In most of the African studies, PM concentrations exceed WHO limits.

Data from African cities on gas phase pollutants are even sparser [11]. Available reports, however, indicate that concentrations of gas phase pollutants are low [13,14,15,16,17,18,19,20,21,22]. Carmichael et al., in an extensive study in Africa, Asia and South America, found that concentrations of gas phase pollutants of SO2, NO2 and ammonia were generally lower in the tropical regions than non-tropical regions of the studied countries [23].

For Uganda, data on air pollution is nearly nonexistent. To date, there is only one publication available, from our group, showing a PM concentration of 100 μg/m3 from a single pilot study measured in one district of Kampala [24]. The 2010 Uganda State of the Environment Report acknowledges this lack of air pollution data for Uganda [25]. The current study expands on our previous air pollution assessment efforts [22] and provides novel data on ambient concentrations of four key air pollutants (PM2.5, NO2, SO2, and O3) at various sites in Kampala and Jinja.

2. Methods

2.1. Study Design

This is a cross-sectional, spatial, pilot assessment of ambient air concentrations of PM2.5, NO2, SO2, and O3 at different sites in three different land use areas in Kampala and Jinja during the period from 30 June to 27 July, 2014.

2.2. Study Sites and Monitoring Approaches

Air pollutant monitoring was conducted in Kampala and Jinja. Kampala, the capital city of Uganda, covers an area of 197 km2 and is spread over 22 hills at an altitude of 1120 m above sea level. The city’s day and night population is 3 million and 1.72 million people, respectively [26]. The day population represents Kampala residents and commuters entering the city from outside regions for work, education and business. Annual rainfall in Kampala ranges from 1750–2000 mm with peak wet seasons from March to May and from September to November. The dry seasons are between June and July, and December and February. The average annual temperature is 21.9° C and relative humidity ranges from 53–89% [27].

Jinja is the second largest city in Uganda, located 80 km east of Kampala and covers a land area of 28 km2 at an altitude of 1230 m above sea level. Jinja has a day population of 300,000 people and a night population of 89,700 people [26]. The annual rainfall averages 1125 mm [28].

Air pollutant sampling sites in both cities were selected to represent different topographies and land use areas: commercial, industrial, and residential. According to the land classification system of local climate zones (LCZ), all of the sampling sites belong to the following categories: open low-rise or sparsely built [29]. Representative photographs of these sites are shown in Figure 1. Sites for PM monitoring were fewer than sites for gas phase pollutant monitoring, as equipment for PM sampling was limited.

Figure 1.

Figure 1

Representative images of sampling sites. Sampling site: a) central monitoring site; b) paved residential; c) unpaved residential, low income; d) industrial area; e) unpaved residential high income; and f) commercial center.

Areas of the cities characterized by high commercial activities such as trading, small-scale manufacturing and high traffic were selected as commercial land use areas. Industrial land use areas were in designated industrial areas of the cities. In Kampala, the industries surrounding the monitoring sites were involved in textile, steel and food products, while in Jinja we observed food products, plastics and steel industries. Land use areas defined as residential were divided into two categories, those with paved/tarmac roads and those with unpaved/murram roads.

Meteorological parameters (temperature and humidity) and O3 were monitored at one central commercial site in Kampala city. Meteorological data (2012–2014) were also retrieved from National Weather Services to compare the year-round meteorological conditions and the meteorological conditions during sampling.

2.3. Air Pollutant Sampling Methods

PM2.5 concentrations were measured over periods of 24 hours from 30 June to 27 July 2014 with a real-time aerosol monitor, DUSTTRACK II-8530 (TSI Inc, Shoreview, MN) at 18 sites (15 in Kampala and 3 in Jinja) that can assess PM2.5 concentrations in a range from 1 µg/m3 to 400 mg/m3. Prior to all measurements, the DUSTTRACK monitor was calibrated using the federal reference method, and zero-calibrated prior to each sampling session. All data were saved on the monitor until the end of study when it was downloaded into an excel database for analysis in Stata 11.2.

Concentrations of NO2 and SO2 were measured with Combo diffusion tubes (NO2 and SO2, Ormantine, FL, USA) at 28 study sites (22 in Kampala and 6 in Jinja). At each study site, two duplicate diffusion tubes were secured on the outside walls of selected buildings, 3–5 meters above ground. Sampling sites were selected to reflect different land use patterns and geographic topography, and each building was at least 3 meters away from immediate emission sources. The sampling height was selected for the safety of the passive samplers and was within the USEPA ambient monitoring siting criteria (i.e., < 15 m). Each passive diffusion tube was exposed to ambient air for two weeks. Sampling starting and sampling end times were recorded. Two traveling blanks were included for each city. Prior to, and following, sampling periods, the samplers were stored at 4 °C. Combo diffusion tubes were shipped to Gradkos laboratory in England where NO2 and SO2 analyses were conducted on a Dionex ICS1100 ICU10 ion chromatography system (Thermo Fisher Scientific Inc., Waltham, MA, USA). O3 was measured with a federal equivalent real-time monitor (POM, 2B Technologies, CO, USA) that was calibrated before the study period, and cleaned daily during the sampling period.

2.4. Meteorological Measurements

Temperature and humidity were monitored daily for the first seven days of the study period with a real-time monitor (HOBO U23, OnSet, MA, USA). The monitor was calibrated prior to sampling, and cleaned daily during the sampling period.

2.5. Data Analysis

Data from all monitors were downloaded directly into a Microsoft Excel database and analyzed using Stata 11.2 (StataCorp LP, College Station, TX). Descriptive statistics were used to summarize all pollutant concentrations and meteorological data. Mean pollutant concentrations were compared between land use areas and cities by t-tests. A p-value of <0.05 was considered statistically significant. Concentrations of travelling blanks (i.e., tubes not exposed to sampling environments) were subtracted from all measured SO2 and NO2 concentrations prior to statistical analysis.

2.6. Ethics Approval

The study protocol was approved by the Mulago Hospital Research and Ethics Committee and the Uganda National Council for Science and Technology.

3. Results

3.1. Temperature and Humidity

Temperature and relative humidity were measured at the central monitoring location during the first week (30 June to 5 July, 2014) of sampling. The mean (± standard deviation (SD)) ambient temperature was 24.7 ± 1.9 °C (maximum 26.4 °C, minimum 21.1 °C). Mean humidity was 63.5% ± 5.7 (maximum 74.4%, minimum 58.0%). We did not monitor temperature and humidity data further due to limited equipment availability. Archived temperature and humidity data from the National Weather Services (at Entebbe Airport) was used instead and is presented in Table 1 showing largely constant weather conditions during the entire air pollution monitoring period.

Table 1.

Meteorological conditions during sampling days.

Sampling Date Minimum Temperature °C Maximum Temperature °C Average Temperature °C Average Relative Humidity % Wind Speed Km/h Precipitation mm
30 June 19 26 22 80 8 0.0
1 July 18 26 22 77 8 0.0
2 July 18 26 22 77 8 0.0
3 July 19 26 22 80 10 0.0
4 July 19 26 22 76 7 0.0
5 July 17 26 22 76 9 0.0
6 July 19 26 22 70 9 0.0
7 July 18 25 22 81 11 0.0
8 July 18 25 22 75 11 0.0
9 July 19 20 20 96 4 0.0
10 July 18 23 --* -- -- --
11 July 17 24 20 76 11 0.0
12 July 20 23 22 84 10 0.0
13 July 19 25 22 76 9 0.0

* Data were missing, ** The historical minimum and maximum temperatures during the dry season are 18 and 28 °C for January, 18 and 28 °C for February, 17 and 25 °C for June, 17 and 25 °C for July, 16 and 25 °C for August, and 17 and 27 °C for December.

3.2. PM2.5

PM2.5 concentrations were measured at 18 sites for an average sampling period of 21 hours and 15 minutes (maximum 24 hours, minimum 7 hours). Spatial variations of PM2.5 pollution levels in Kampala are shown in Figure 2a.

Figure 2.

Figure 2

The spatial variation of PM2.5 (a) and NO2 (b) in Kampala.

The PM2.5 concentrations by sampling site are presented in a supplementary Table S1. The mean 24-hour PM2.5 concentrations calculated for all study sites was 132.1 μg/m3. The concentration measured by the real-time monitor was comparable to the filter-based approach. At the central monitoring site (city center), the PM2.5 mass concentrations were 90.4 µg/m3 obtained from the filter-basedapproachvs. 94.0 µg/m3 obtained from the real-time monitor. By city, 24-hour mean PM2.5 concentrations in Kampala were higher than in Jinja, but the difference did not reach statistical significance (138.6 μg/m3 and 99.3 μg/m3, p = 0.20). By land use, PM2.5 and nitrogen dioxide pollution levels are shown in Table 2. The highest 24-hour mean PM2.5 concentrations were observed at the industrial (156 μg/m3) followed by residential areas with unpaved roads (152.6 μg/m3) and commercial land use areas (129.4 μg/m3). Residential and office areas with paved roads had the lowest mean PM concentrations (88.3 μg/m3). Compared to residential areas with paved roads, residential areas with unpaved roads had significantly higher mean 24-hour PM2.5 concentrations (152.6 μg/m3 vs. 88.3 μg/m3, p = 0.045). Considering both industrial and commercial areas as nonresidential, no significant differences were noted between nonresidential and residential areas (131.0 μg/m3 vs. 132.8 μg/m3, p = 0.93). The 24-hour mean PM2.5 concentration at a site in Jinja with unpaved roads was comparable to sites with unpaved roads in Kampala (161 μg/m3 vs. 151.4 μg/m3). The mean PM2.5 concentration at sites with paved roads in Jinja, however, was lower than that at similar sites in Kampala (68.5 μg/m3 vs. 108.0 μg/m3).

Table 2.

PM2.5 and NO2 concentration by land use.

Land Use Category PM2.5 NO2
Mean (SD) 24 Hour Average Mean (SD) Minimum Mean (SD) Maximum Mean (SD) NO2 (µg/M3) Mean (SD) NO2 (Ppb)
Commercial Area 129.4 (38) 4.82 (31) 284.4 (89) 32.19 (12.19) 16.79 (6.49)
Industrial Area 156 (0) 8.2 (0) 384 (0) 22.69 (5.76) 11.76 (2.99)
Residential Unpaved (Murram) Road 152.6 (44) 23.1 (35) 346.1 (95) 20.09 (5.67) 11.61 (4.88)
Residential/Office Paved (Tarmac) 88.3 (50) 3.9 (27) 155 (66) 18.39 (4.39) 11.43 (3.16)

3.3. Gas Phase Pollutants

Duplicate diffusion tubes were used for sampling SO2 and NO2 at each monitoring site. Each tube can simultaneously collect NO2 and SO2. The concentrations of NO2 and SO2 at each monitoring site were calculated as the average of the readings of the two tubes.

NO2 and SO2 concentrations were measured at a total of 28 monitoring sites (22 in Kampala and six in Jinja). In Kampala, one of the SO2 duplicate tubes could not be retrieved at two monitoring sites. In Jinja, both NO2 tubes could not be retrieved at one site and one SO2 tube only was retrieved at one site. Therefore, 27 NO2 and SO2 sampling tubes were available for analysis (22 from Kampala and five from Jinja). The mean monitor exposure time was 330.34 (±25.54) hours or 13 days and 19 hours. The overall precision, expressed as coefficient of variation based on 22 pairs of co located sampling, was 14.0%.

3.3.1. Nitrogen Dioxide

NO2 concentrations determined at the different sampling sites are shown in supplementary Table S2. The mean two-week NO2 concentration was 24.9 µg/m3.

By city, Kampala air was characterized by a higher mean total NO2 concentration than that of Jinja (26.69 µg/m3 vs.17.49 µg/m3, p = 0.07). The spatial variations of NO2 concentration levels in Kampala are shown in Figure 2b.

NO2 concentrations by land use are shown in Table 2. The highest NO2 concentrations were observed in commercial land use areas (32.19 µg/m3) and the lowest in residential land use areas with paved roads (18.39 µg/m3). The mean NO2 concentrations in commercial (including industrial) land use areas were significantly higher than in residential land use areas (32.19 µg/m3 vs. 19.69 µg/m3, p = 0.002). NO2 concentrations measured in residential land use areas did not significantly differ from those in industrial land use areas (19.69 µg/m3 vs. 22.69 µg/m3, p = 0.46). Similarly, NO2 concentrations in commercial land use areas did not significantly differ from those in industrial land useareas(32.19µg/m3vs. 22.69 µg/m3, p = 0.22).

3.3.2. Sulfur Dioxide

SO2 was measured at all study sites and in all land use areas where NO2 was measured. Levels of detectable SO2 concentrations are shown in supplementary Table S3. SO2 concentrations were below detection limit (<0.03 µg/m3) at 20 of the 27 monitoring sites. The two-week mean SO2 concentration at all monitoring sites was 3.79 ± 3.0 µg/m3.

By city, there was only one monitoring site in Jinja where SO2 concentrations reached detectable levels. This site, in an industrial land use area of Jinja, had a higher SO2 concentration level (7.3 µg/m3) than that in the industrial land use area of Kampala (<0.69 µg/m3). Six other monitoring sites in Kampala also showed SO2 concentrations above detection limit (mean 3.11 µg/m3). Comparing SO2 concentrations by land use, concentrations were highest in industrial land use areas (7.39 µg/m3), followed by commercial land use areas (3.69 µg/m3), then residential land use areas with paved roads (2.79 µg/m3), or unpaved roads (2.39 µg/m3).

3.3.3. Ozone

The mean one-hour O3 concentration at the monitoring site established at Lourdel Road, Wandegeya in Kampala measured over a period of seven days was 11.4 μg/m3 (±4.8 μg/m3). O3 concentrations varied considerably across the sampling period (Figure 3).

Figure 3.

Figure 3

Distribution of O3 concentrations (1-min average) measured at the central monitoring site in Kampala.

4. Discussion

This pilot study demonstrates presence of high PM concentrations and low gas phase air pollutant levels in Kampala and Jinja between 30 June and 17 July, 2014. The observed mean PM2.5 concentration of 132.1 μg/m3 (5.3-fold above the limit defined by WHO) across all monitoring sites in the current study is comparable with the mean PM2.5 concentration of 104.9 μg/m3 described in an earlier single-site pilot study from a district in Kampala [24]. As expected, particulate air pollution levels were found to be greatest in areas with high commercial/industrial land use and unpaved roads.

The observed mean PM2.5 concentration of 132.1 μg/m3 in the current study clearly exceeds the mean PM concentration of 78 μg/m3 calculated for the African region and reported in the WHO 2014 publication of the global state of air quality from 1600 cities in 91 countries [12]. Within the East African region, however, the mean PM concentration (132.1 μg/m3) observed in the current study is comparable with that reported from Nairobi/Kenya (128.7 μg/m3) and significantly higher than that reported from Dar es Salaam/Tanzania (26 μg/m3) [17,30].

Sources of particulate air pollution described in the studies of African cities are typically emissions from vehicles, re-suspended dust from unpaved roads, smoke from indoor biomass fuel use and garbage burning, and industrial sites [14,31,32]. During the current study, we observed source emissions of dust and soil blown by wind from unpaved roads, black smoke exhausts from cars, trucks and busses and smoke from burning household garbage in both Kampala and Jinja. High PM levels in residential land use areas with unpaved roads without industrial activity or high traffic volume, suggest that re-suspended dust significantly contributes to high PM levels. High PM levels in commercial land use areas with high traffic volume and paved roads, in contrast, suggest that vehicle emissions represent another significant source of PM in Kampala and Jinja. Dust from unpaved roads in the suburbs of both cities appears to be carried by human activities into areas with paved roads.

Ambient air PM composition has been reported in some African cities [16,24,33]. Our earlier pilot study in Kampala found that more than 90% of PM2.5 studied at a sampling site in the Mpererwe district of Kampala was comprised of crustal species (probably re-suspended soil dust) and carbonaceous aerosol [24]. In Dar es Salaam, a study of PM collected close to a vehicle traffic site found carbon to be the main component suggesting vehicular emissions as its main source [33]. In Nairobi, Gaita et al. found that vehicle traffic, mineral dust, industrial activity, combustion and a mixed factor (composed of biomass burning, secondary aerosol and aged sea salt) were the main sources of PM air pollution [32]. Mineral dust and traffic were responsible for approximately 74% of PM2.5 mass [32]. Based on our findings and observations in the current pilot study we speculate that re-suspended dust and vehicular emissions are the primary sources of PM2.5 in Kampala and Jinja and may also be significant contributors to air pollution in other African cities.

We also assessed the concentration of three key gas phase pollutants (NO2, SO2 and O3) in Kampala and Jinja. Even though concentrations of NO2, SO2 and O3 were below WHO guideline levels (200 μg/m3 one-hour mean, 20 μg/m3 24-hour mean and 100 μg/m3 eight-hour mean, respectively [2]) we recognize that our findings cannot be directly compared with WHO air quality standards due to differences in averaging times. However, our findings are comparable with findings from other gas phase pollutant studies in Africa [13,14,15,17]. We do not know why gas phase pollutants in our study and other studies from Africa are low. Climatic conditions in the studied areas may facilitate adsorption of gas phase pollutants onto PM. As PM concentrations were found to be high in the current study and other studies in Africa this may explain the observed low concentrations of gas phase pollutants.

Conclusions from the current cross sectional study have to be made considering that temporal variations of air pollutant concentrations could not be assessed, which is a major limitation of this pilot study, especially for PM2.5. Due to the limitation of the number of real-time instruments (i.e., only one DustTrack), we could not measure PM2.5 concentrations at multiple sites at the same time. Therefore, we were unable to differentiate spatial variation from temporal variation in PM2.5 concentrations. However, the meteorological data in Table 1 suggests that the weather conditions during our measurements were quite consistent, minimizing the possibility of the impact of weather on PM2.5 concentrations. Given that this study was conducted within a short period of time, source emission profiles in different locations will not be expected to change dramatically. Therefore, the measured PM2.5 spatial variation at minumum suggests the heterogeneous pattern of PM2.5 in Kampala.

In addition, PM2.5 concentrations (132.1 μg/m3) observed in this study (dry season) are consistent with findings from our earlier study, in which PM2.5 (104.3 μg/m3) was collected in December 2013 (also a dry season). Meteorological conditions during this pilot study were typical in Kampala for dry seasons, as shown in Table 1. We are aware of the impact of weather and seasonal variations on air pollutant concentrations and expect PM2.5 concentrations to be different in rainy seasons. Future studies will have to expand air pollution monitoring to other cities and parts of Uganda, cover all weather seasons and begin exploring air pollution effects on public health, in particular lung health in urban populations of Uganda.

5. Conclusions

This study suggests that high level PM air pollution is prevalent in urban and suburban areas in Uganda, with PM2.5 concentrations above 100 µg/m3 in multiple locations in Kampala. Land use characteristics define ambient PM2.5, NO2 and SO2 concentrations. Long-term exposures to the observed high levels of air pollution likely represent a major risk to public health in Kampala and Jinja. Long-term studies are needed to assess air pollution levels during the course of multiple weather seasons and the health impact in exposed populations.

Acknowledgements

The authors wish to thank Yale University office of Global Health, International Primary Care Respiratory Group, Center for Global Public Health at Rutgers School of Public Health, Rutgers Centers for Global Advancement and International Affairs (GAIA Centers), NIEHS R01ES020382-02 (S. Schwander), American Lung Association SB230016N (for Q Meng), and PES005022 for funding the study. We also thank Prof. Asghar Rastegar from the Yale University School of Medicine for his guidance during the design and implementation of this project. Special thanks go to Ms. Laura Crawford from the Yale University office of Global Health for her exemplary organization of the study equipment and logistics and to the research assistants (Stephen Kyaligonza and Simon Onanyang) for their dedicated efforts during data collection. We thank Dr. Denis Bwayo and Mr. Ahmed Mawa for their assistance with identification of the sampling sites in Jinja.

Supplementary Tables

Table S1.

PM2.5 concentrations at different sites in Kampala and Jinja.

Site City Land Use Test Length (H: Min) PM 2.5 Concentration, µg/M3 Time Min (H:Min:S) Time Max (H:Min:S)
24 hour Average Min Max
Bugolobi Kampala Residential/office paved (tarmac) road 24:00 163 66 254 16:18 23:18:48
Kampala Industrial Area Kampala Industrial area 23:35 156 82 384 16:04:46 23:04:46
Kisimira Road Jinja Residential/office paved (tarmac) road 24:00 68 39 119 6:02:42 21:02:42
Rippon garden Nile Avenue Jinja Residential/office paved (tarmac) road 24:00 69 50 124 16:04:15 8:04:15
School village Tenywa Road Walukuba East Jinja Residential unpaved (murram) road 18:46 161 0 285 11:45:21 18:45:21
Kabowa Gabunga Road Kampala Residential unpaved (murram) road 24:00 156 40 362 14:45:47 7:45:47
Kamwokya, Kyebando Road Kampala Commercial area 24:00 88 0 217 13:05:53 14:05:53
Katanga, Wandegeya Kampala Commercial area 24:00 108 52 248 6:56:31 18:56:31
Kawala Bwaise Road Kampala Residential unpaved (murram) road 23:35 135 0 291 13:54:31 21:54:31
Kiwatule Central 1 Kampala Residential unpaved (murram) road 7:00 114 90 22 17:43:30 20:43:30
Kololo Ekobo Road Kampala Residential/office paved (tarmac) road 18:00 53 2 123 17:43:28 10:43:28
Kyanja Nazareth Road Kampala Residential unpaved (murram) road 24:00 100 55 317 11:15:43 21:15:43
Lungujja Busega Kibumbiro Kampala Residential unpaved (murram) road 22:09 240 0 535 7:38:18 8:38:18
Mulago Mulago Hill Road Kampala Commercial area 24:00 143 59 225 9:43:39 2:43:39
Amir street Nakasero Kampala Commercial area 19:00 187 85 434 16:14:20 2:14:20
Nalukolongo Kweba Zone Kampala Residential unpaved (murram) road 18:16 133 0 401 9:28:42 0:28:42
Nansana Naluvule Kampala Residential unpaved (murram) road 22:32 182 0 358 14:26:25 23:26:25
Lourdel Road, wandegeya Kampala Commercial area 17:00 121 45 298 21:57:34 1:57:34

Table S2.

Concentration of ambient air nitrogen dioxide at different sites in Kampala and Jinja cities.

Site Land Use City Exposure NO2, total (µg) NO2, µg/m3 NO2 ppb
Amir Street–Nakasero Commercial center Kampala 309.55 1.15 49.90 26.96
Mutundwe–Kigaga Zone Residential unpaved (murram) road Kampala 337.75 0.25 9.32 4.85
Nalukolongo–Kweba Zone Residential unpaved (murram) road Kampala 337.67 0.67 26.22 13.64
Kawala–Bwaise Road Residential unpaved (murram) road Kampala 339.50 0.62 24.33 12.66
Kiwat ule Central I. Residential unpaved (murram) road Kampala 336.00 0.56 22.08 11.48
Bwaise–Makerere–Kavule Road Residential unpaved (murram) road Kampala 308.43 0.54 23.33 12.13
Bwaise, x Road Commercial center Kampala 337.00 0.61 24.15 12.56
Kabowa–Gabunga Road Residential unpaved (murram) road Kampala 338.07 0.59 23.00 11.96
Lungunja–Busega–Kibumbiro Residential unpaved (murram) road Kampala 335.00 0.50 19.71 10.25
Rippon Garden–Nile Avenue Residential/office paved (tarmac) road Jinja 337.07 0.49 19.25 10.01
School Village–Tenywa Road Walukuba East Residential unpaved (murram) road Jinja 336.83 0.27 10.48 5.45
Walukuba - Masese Road Commercial center Jinja 336.42 0.29 11.14 5.79
Mulago Hill Road 1 Commercial center Kampala 343.55 0.59 22.79 11.85
Mulago Hill Road 2 Commercial center Kampala 311.63 0.78 31.78 16.53
Bugolobi Residential/office paved (tarmac) road Kampala 336.63 0.39 15.23 7.92
Banda Zone B8–Banda Nalya Road Commercial center Kampala 332.48 0.68 27.22 14.15
Namugongo Road, Kireka Commercial center Kampala 332.45 1.31 52.90 27.51
Katanga, Wandegeya Commercial center Kampala 331.50 0.81 32.72 17.02
Kawempe–Mbogo Road Residential/office paved (tarmac) road Kampala 333.50 0.61 24.14 12.55
Nansana–Nalvule Residential unpaved (murram) road Kampala 332.42 0.53 21.26 22.70
Mbuya–Nadiope Residential/office paved (tarmac) road Kampala 215.05 0.24 14.63 15.22
Lourdel road, Wandegeya Commercial center Kampala 360.00 1.13 42.08 21.88
Kamwokya–Kyebando Road Commercial center Kampala 336.92 0.79 31.22 16.23
Kyanja–Nazereth Rd/Kyanja Road Residential unpaved (murram) road Kampala 356.12 0.57 21.19 11.02
5th Street Industrial Area Industrial area Kampala 334.02 0.67 26.67 13.87
Nizam Road, Jinja center Commercial center Jinja 335.50 0.69 27.37 14.23
Industrial Area—Jinja Industrial area Jinja 338.15 0.47 18.53 9.64

Table S3.

Concentration of Sulphur dioxide at sites with detectable Sulphur dioxide concentrations.

Site Land Use City Exposure Total SO2 (µg) SO2 (µg/m3) SO2 (ppb)
Kabowa-Gabunga Road Residential unpaved (murram) road Kampala 338.07 0.05 2.34 0.88
Mulago Hill road 1 Commercial centre Kampala 311.63 0.04 1.73 0.65
Bugolobi Residential/office paved (tarmac) road Kampala 336.63 0.04 1.81 0.68
Banda Zone B8-Banda Nalya Road Commercial centre Kampala 332.48 0.1 8.35 3.13
Namugongo Road-Kireka road Commercial centre Kampala 332.45 0.03 0.77 0.29
Kawempe-Mbogo Road Residential/office paved (tarmac) road Kampala 333.5 0.06 3.65 1.37
Industrial Area-Jinja Industrial area Jinja 338.15 0.09 7.31 2.74

Author Contributions

Bruce Kirenga, Qingyu Meng, Stephan Schwander and Vahid Mohsenin conceived the study; Bruce Kirenga, Meng Qingyu, Stephan Schwander and Vahid Mohsenin designed the experiments; Bruce Kirenga, Meng Qingyu, Gerald Obai and Hellen Aanyu performed the experiments; Bruce Kirenga, Meng Qingyu, and Achilles Katamba analyzed the data; Bruce Kirenga, Meng Qingyu, Stephan Schwander, Vahid Mohsenin, Thys van der Molen, and Frederik van Gemert contributed reagents/materials/analysis tools; and all authors participated in the writing of the paper.

Conflicts of Interest

The authors declare no conflict of interest.

References

  • 1.7 Million Premature Deaths Annually Linked to Air Pollution. [(accessed on 22 August 2014)]. Available online: http://www.who.int/mediacentre/news/releases/2014/air-pollution/en/ [PubMed]
  • 2.World Health Organisation Health Topics. Air Pollution. [(accessed on 1 May 2014)]. Available online: http://www.who.int/topics/air_pollution/en/
  • 3.Environmental Working Group Body Burden–—The Pollution in Newborns. A Benchmark Investigation of Industrial Chemicals, Pollutants and Pesticides in Umbilical Cord Blood. [(accessed on 14 July 2005)]. Available online: http://www.ewg.org/research/body-burden-pollution-newborns.
  • 4.Salvi S. Health effects of ambient air pollution in children. Paediatr. Respir. Rev. 2007;8:275–280. doi: 10.1016/j.prrv.2007.08.008. [DOI] [PubMed] [Google Scholar]
  • 5.Kajekar R. Environmental factors and developmental outcomes in the lung. Pharmacol. Ther. 2007;114:129–145. doi: 10.1016/j.pharmthera.2007.01.011. [DOI] [PubMed] [Google Scholar]
  • 6.Fleischer N.L., Merialdi M., van Donkelaar A., Vadillo-Ortega F., Martin R.V., Betran A.P., Souza J.P., O’Neill M. Outdoor air pollution, preterm birth, and low birth weight: analysis of the world health organization global survey on maternal and perinatal health. Environ. Health Perspect. 2014;122:425–430. doi: 10.1289/ehp.1306837. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Fenger J. Urban air quality. Atmospheric Environ. 1999;33:4877–4900. doi: 10.1016/S1352-2310(99)00290-3. [DOI] [Google Scholar]
  • 8.Clean Air Act. [(accessed on 22 August 2014)]; Available online: http://www.epw.senate.gov/envlaws/cleanair.pdf.
  • 9.World Health Organization . WHO Air Quality Guidelines for Particulate Matter, Ozone, Nitrogen Dioxide and Sulfur Dioxide: Global Update 2005: Summary Of Risk Assessment. WHO; Geneva, Switzerland: 2006. [Google Scholar]
  • 10.National Ambient Air Quality Standards (NAAQS) [(accessed on 22 August 2014)]; Available online: http://www.epa.gov/air/criteria.html.
  • 11.Petkova E.P., Jack D.W., Volavka-Close N.H., Kinney P.L. Particulate matter pollution in African cities. Air Quality Atmos. Health. 2013;6:603–614. doi: 10.1007/s11869-013-0199-6. [DOI] [Google Scholar]
  • 12.Ambient (Outdoor) Air Pollution in Cities Database 2014. [(accessed on 22 August 2014)]. Available online: http://www.who.int/phe/health_topics/outdoorair/databases/cities/en/
  • 13.Khoder M.I. Diurnal, seasonal and weekdays-weekends variations of ground level ozone concentrations in an urban area in greater Cairo. Environ. Monit. Assess. 2009;149:349–362. doi: 10.1007/s10661-008-0208-7. [DOI] [PubMed] [Google Scholar]
  • 14.Arku R.E., Vallarino J., Dionisio K.L., Willis R., Choi H., Wilson J.G., Hemphill C., Agyei-Mensah S., Spengler J.D., Ezzati M. Characterizing air pollution in two low-income neighborhoods in Accra, Ghana. Sci Total Environ. 2008;402:217–231. doi: 10.1016/j.scitotenv.2008.04.042. [DOI] [PubMed] [Google Scholar]
  • 15.Moodley K.G., Singh S., Govender S. Passive monitoring of nitrogen dioxide in urban air: A case study of Durban metropolis, South Africa. J. Environ. Manage. 2011;92:2145–2150. doi: 10.1016/j.jenvman.2011.03.040. [DOI] [PubMed] [Google Scholar]
  • 16.Etyemezian V., Tesfaye M., Yimer A., Chow J., Mesfin D., Nega T., Nikolich G., Watson J.G., Wondmagegn M. Results from a pilot-scale air quality study in Addis Ababa, Ethiopia. Atmos. Environ. 2005;39:7849–7860. doi: 10.1016/j.atmosenv.2005.08.033. [DOI] [Google Scholar]
  • 17.Jackson M.M. Roadside concentration of gaseous and particulate matter pollutants and risk assessment in Dar-es-Salaam, Tanzania. Environ. Monit. Assess. 2005;104:385–407. doi: 10.1007/s10661-005-1680-y. [DOI] [PubMed] [Google Scholar]
  • 18.Lindén J. Intra-urban air pollution in a rapidly growing Sahelian city. Environ. Int. 2012;40:51–62. doi: 10.1016/j.envint.2011.11.005. [DOI] [PubMed] [Google Scholar]
  • 19.Josipovic M., Annegarn H.J., Kneen M.A., Pienaar J.J., Piketh S.J. Concentrations, distributions and critical level exceedance assessment of SO2, NO2 and O3 in South Africa. Environ. Monit. Assess. 2010;171:181–196. doi: 10.1007/s10661-009-1270-5. [DOI] [PubMed] [Google Scholar]
  • 20.Kilabuko J.H., Matsuki H., Nakai S. Air quality and acute respiratory illness in biomass fuel using homes in Bagamoyo, Tanzania. Int. J. Environ. Res. Public Health. 2007;4:39–44. doi: 10.3390/ijerph2007010007. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.El-Dars F.M.S. Monitoring ambient sulfur dioxide levels at some residential environments in the Greater Cairo urban Region—Egypt. Environ. Monit. Assess. 2004;95:269–286. doi: 10.1023/B:EMAS.0000029908.56178.5a. [DOI] [PubMed] [Google Scholar]
  • 22.Adon M., Glay-Lacaux C., Yoboue V., Delon C., Lacaux J.P., Castera P., Gardrat E., Pienaar J., Al Ourabi H., Laouali D., et al. Long term measurements of sulfur dioxide, nitrogen dioxide, ammonia, nitric acid and ozone in Africa using passive samplers. South Afr. J. Sci. 2007;103:336–342. [Google Scholar]
  • 23.Carmichael G.R., Ferm M., Thongboonchoo N., Woo J.-H., Chan L., Murano K., Viet P.H., Mossberg C., Bala R., Boonjawat J. Measurements of sulfur dioxide, ozone and ammonia concentrations in Asia, Africa, and South America using passive samplers. Atmos. Environ. 2003;37:1293–1308. doi: 10.1016/S1352-2310(02)01009-9. [DOI] [Google Scholar]
  • 24.Schwander S., Okello C.D., Freers J., Chow J.C., Watson J.G., Corry M. Ambient particulate matter air pollution in Mpererwe District, Kampala, Uganda: A pilot study. J. Environ. Public Health. 2014 doi: 10.1155/2014/763934. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.State of the Environment Report For Uganda 2010. [(accessed on 22 August 2014)]. Available online: http://library.health.go.ug/publications/service-delivery-public-health/environment-and-sanitation/state-environment-report.
  • 26.Uganda Statistical Abstract 2012. [(accessed on 22 August 2014)]. Available online: http://www.ubos.org/onlinefiles/uploads/ubos/pdf%20documents/2012StatisticalAbstract.pdf.
  • 27.District Profile. [(accessed on 22 August 2014)]. Available online: http://ww2.unhabitat.org/programmes/ump/documents/kampala_cds.doc.
  • 28.Jinja Municipality Profile. [(accessed on 22 August 2014)]. Available online: http://www.skelleftea.se/Skol%20och%20kulturkontoret/Innehallssidor/Bifogat/JINJA%20MUNICIPALITY%20PROFILE.pdf.
  • 29.Stewart I.D., Oke T.R. Local climate zones for urban temperature studies. Bulletin Amer. Meteorol. Soc. 2012;93:1879–1900. doi: 10.1175/BAMS-D-11-00019.1. [DOI] [Google Scholar]
  • 30.Kinney P.L. Traffic impacts on PM(2.5) air quality in Nairobi, Kenya. Environ. Sci. Policy. 2011;14:369–378. doi: 10.1016/j.envsci.2011.02.005. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31.Ofosu F.G., Hopke P.K., Aboh I.J., Bamford S.A. Biomass burning contribution to ambient air particulate levels at Navrongo in the Savannah zone of Ghana. J. Air Waste Manag. Assoc. 2013;63:1036–1045. doi: 10.1080/10962247.2013.783888. [DOI] [PubMed] [Google Scholar]
  • 32.Gaita S., Boman J., Gatari M., Pettersson J., Janhäll S. Source apportionment and seasonal variation of PM 2.5 in a Sub-Saharan African city: Nairobi, Kenya. Atmos. Chem. Phys. 2014;14:9977–9991. doi: 10.5194/acp-14-9977-2014. [DOI] [Google Scholar]
  • 33.Mkoma S.L., Chi X., Maenhaut W. Characteristics of carbonaceous aerosols in ambient PM10 and PM2.5 particles in Dar es Salaam, Tanzania. Sci Total Environ. 2010;408:1308–1314. doi: 10.1016/j.scitotenv.2009.10.054. [DOI] [PubMed] [Google Scholar]

Articles from International Journal of Environmental Research and Public Health are provided here courtesy of Multidisciplinary Digital Publishing Institute (MDPI)

RESOURCES