Table 7. Summary of Countercurrent Separation Elution Methods: Elution-Extrusion Countercurrent Chromatography (EECCC), Back-Extrusion Countercurrent Chromatography (BECCC), and Intermittent Countercurrent Extraction (ICcE).
| elution method | phase changea | flow direction change | rotation direction change | comments |
|---|---|---|---|---|
| classical | highly retained analytes remain in stationary phase | |||
| EECCC | single | analytes elute in order of K values | ||
| BECCC | single | elution order reverses; some analytes may elute at separate volumes | ||
| back-step CCC | twice | a plug of aqueous phase introduced to elute highly retained analytes | ||
| dual-mode | single | single | elution order reverses | |
| dual-rotation | single | single | elution order reverses | |
| multiple dual-mode | multiple | multiple | elution order reverses each cycle | |
| ICcE | multiple | multiple | sample loop is in the middle of a single column or between two separate columns |
Phase change refers to switching mobile and stationary phase.