Skip to main content
. Author manuscript; available in PMC: 2016 Oct 1.
Published in final edited form as: Biomaterials. 2015 Jul 2;66:1–8. doi: 10.1016/j.biomaterials.2015.07.002

Table 1. Characterization Results of Synthesized Polymeric Fluorogens.

Entry Mn Đ DP EO KD kON τdc Brightness

(#) (g/mole) (n) (m) (nM) (M-1*s-1) (μs) (kHz)
1 177,400 1.26 372 8.5 33 1.36E4 611 6.499
2 71,820 1.20 150 8.5 42 1.62E4 490 6.728
3 43,560 1.20 90 8.5 29 1.89E4 363 7.052
4 31,970 1.40 66 8.5 10 3.98E4 353 7.323
5 49,890 1.31 164 4.5 4.7 3.14E4 404 7.573
6 38,750 1.33 164 3.0 6.0 3.36E4 377 9.230
7 180,200 1.82 202 19.3 -- -- 532 7.678
8 23,130 1.44 120 2.0 -- -- -- --
9a 97,960 1.84 204 8.5 1.9 3.46E4 -- 6.855
MG-Esterb -- -- -- -- 0.15 8.2E6 217 7.720
a

MG amide initiator containing a longer linker was used instead of PBiB-MG.

b

KD and kON values were obtained from J. Mol. Biol. 2013, 425, 4595.

c

Diffusion correlation time from FCS measurements by fitting autocorrelation curves using a one component 3-D diffusion model.