Skip to main content
. Author manuscript; available in PMC: 2015 Aug 4.
Published in final edited form as: Ophthalmology. 2013 May 21;120(10):1973–1976. doi: 10.1016/j.ophtha.2013.03.013

Table 1. Baseline Characteristics.

Age at surgery (mos)
 Mean ± SD 2.4±1.7
 Range 0.2–7.7
Gender (female/male) 30/20
Ethnicity
 Black 10
 White 38
 Asian 1
 Hispanic 1
Preoperative axial length (mm)
 Mean ± SD 17.3±1.4
 Range 14.2–21.1
Preoperative keratometry (D)
 Mean ± SD 47.8±3.6
 Range 42.5–63.5
Preoperative corneal diameter (mm)
 Mean ± SD 10.1±0.7
 Range 8.5–11.5
Laterality
 Unilateral 20
 Bilateral 30
Right eye/left eye 27/23
CL power used (D)
 32 30
 29 16
 26 2
 23 1
 18 1
Follow-up (days)
 Mean ± SD 11.9±10.2
 Range 1–30
Refraction over CL (D as SE)
 Mean ± SD −0.1±4.0
 Range −13 to +11
CL refraction (D)
 Mean ± SD 29.6±4.8
 Range 15.6–41.7
CL required (including +2 D near focus)
 Mean ± SD 31.6±4.8
 Range 17.6–43.7

CL = contact lens; D = diopter; SD = standard deviation; SE = spherical equivalent.