Table 5.

Fluorescence intensity of SaOS-2 attached on titanium disks.

Radiation dose Ti disk N Mean Standard deviation Min Max Median 95% confidence interval P value
Lower Upper
0 Gy TiO 3 12.44 1.18 11.46 13.75 12.11 9.51 15.37 0.050
F-TiO 3 16.69 2.19 15.43 19.22 15.43 11.26 22.12

2 Gy TiO 3 5.38 1.30 3.89 6.31 5.94 2.14 8.61 0.050
F-TiO 3 10.04 3.20 7.85 13.72 8.57 2.09 18.00

4 Gy TiO 3 3.09 1.44 1.59 4.46 3.20 .049 6.66 0.050
F-TiO 3 5.69 0.73 5.16 6.52 5.39 3.88 7.50

6 Gy TiO 3 3.67 0.52 3.10 4.13 3.78 2.37 4.97 0.275
F-TiO 3 4.30 1.28 3.11 5.66 4.14 1.12 7.48

8 Gy TiO 3 3.39 0.41 2.93 3.74 3.49 2.36 4.41 0.827
F-TiO 3 3.28 0.42 3.02 3.76 3.05 2.24 4.31

10 Gy TiO 3 1.37 0.27 1.15 1.68 1.28 0.69 2.05 0.050
F-TiO 3 2.97 0.43 2.56 3.42 2.91 1.89 4.05

P = 0.05, marginally significantly different.