Skip to main content
. 2015 May 28;119(3):232–241. doi: 10.1152/japplphysiol.00787.2014

Table 3.

Reproducibility of the hyperemic and vasodilator kinetic response to rhythmic exercise across multiple trials and varying intensities

Trial 1 Trial 2 P Value CV, %
10% MVC
    FBF amplitude, ml/min 140 ± 17 157 ± 23 0.20 11.8 ± 1.8
    τFBF, no. of duty cycles 5.1 ± 0.8 5.5 ± 1.0 0.39 8.7 ± 1.9
    FVC amplitude, ml·min−1·100 mmHg−1 165 ± 18 181 ± 23 0.18 9.4 ± 1.7
    τFVC, no. of duty cycles 5.3 ± 0.9 5.7 ± 1.0 0.17 5.4 ± 1.8
20% MVC
    FBF amplitude, ml/min 310 ± 47 319 ± 53 0.53 5.3 ± 1.9
    τFBF, no. of duty of cycles 7.3 ± 0.9 7.9 ± 1.1 0.20 8.8 ± 2.5
    FVC amplitude, ml·min−1·100 mmHg−1 333 ± 47 324 ± 45 0.43 6.1 ± 1.2
    τFVC, no. of duty cycles 6.6 ± 0.9 6.8 ± 1.0 0.59 9.0 ± 1.3
30% MVC
    FBF amplitude, ml/min 509 ± 53 507 ± 61 0.90 5.3 ± 2.0
    τFBF, no. of duty cycles 9.1 ± 1.2 8.7 ± 1.1 0.52 9.0 ± 2.4
    FVC amplitude, ml·min−1·100 mmHg−1 505 ± 41 515 ± 33 0.39 3.0 ± 0.7
    τFVC, no. of duty cycles 8.6 ± 1.0 8.4 ± 1.0 0.72 9.6 ± 1.6

Values are means ± SE.

CV, coefficient of variation (presented as mean intra-individual CV).