Skip to main content
. 2015 Jun 25;10:96. doi: 10.1186/s13018-015-0239-z

Table 1.

Comparison between the stiffness of the osteosyntheses with the 2C classical configuration (2C) and the 2C configuration with end caps (2CEC). Lower changes in shifting tests = higher stiffness

2C classical (2C) 2C with end caps (2CEC) P value
(n = 8) (n = 7)
Mean (SD) four-point bending (Nm/mm)
Anterior-posterior 0.52 (0.49) 0.44 (0.11) 0.04a
Posterior-anterior 0.43 (0.11) 0.48 (0.13) 0.89
Lateral-medial 0.70 (0.16) 0.60 (0.19) 0.04a
Medial-lateral 0.76 (0.27) 0.73 (0.25) 0.57
Mean (SD) rotation (Nm/°)
External rotation 0.12 (0.04) 0.10 (0.03) 0.15
Internal rotation 0.11 (0.03) 0.10 (0.03) 0.09
Mean (SD) 9° compression/shifting (mm)
Shifting 9° trochanter major 0.80 (0.65) 1.77 (1.70) 0.06
Shifting 9° crista intertrochanterica 4.56 (2.67) 7.44 (2.48) 0.01a

aAdjusting the results with the Holm-Bonferroni method, the significance of the differences could not be confirmed